Model 110 One Conductor, 10 Amp
|
||
Mounts at the end of a rotating axis. Mount by the press fit receptacle accessory. Wire attaches using the accessory receptacle or cap. |
Model No. | Terminals | Voltage AC/DC |
Amp Rating @240VAC |
Max. Freq. MHz |
Contact Resistance |
Max. RPM |
Temp Max. F (C) / Min. F (C) |
Rotation Torque (gm-cm) |
Circuit Separation |
110 | 1 | N/A | 10 | 200 |
|
3600 | 140 (60) /-20(-29) | 35 | N/A | ||
110-SS | 1 | N/A | 10 | 200 |
|
3600 | 140 (60) /-20(-29) | 35 | N/A | ||
110-L | 1 | N/A | 10 | 200 |
|
1200 | 140 (60) /-20(-29) | 10 | N/A |
110 Accessories |
5920 one contact receptacle |
5921-S one contact receptacle w/ 6" wire |
5952 one contact cap w/solder lug |
55337 ring terminal (12-10 AWG) |
||
Receptacle used for mounting to rotating device. |
110 Connections |
|
|
Note: The metal receptacle used for mounting is electrically conductive. Therefore, if desired, it can be used as the electrical connection between the 110 and the rotating member of the machine using Part #5920. However, if an insulated mounting at the rotating member is being used, then Part #5921-S with six inch wire lead is used for the electrical connection. |
110 Suggested Mounting Methods | ||||||||||||||||||||
|
||||||||||||||||||||
|
||||||||||||||||||||
Installation Notes:
|
Model 110-T One Conductor, 10 Amp Model 105 One Conductor, 4 Amp |
||
Mounts at the end of a rotating axis. Mount by the press fit receptacle accessory. Wires attach using the accessory receptacle and cap. |
Model No. | Terminals | Voltage AC/DC |
Amp Rating @240VAC |
Max. Freq. MHz |
Contact Resistance |
Max. RPM |
Temp Max. F (C) / Min. F (C) |
Rotation Torque (gm-cm) |
Circuit Separation |
110-T | 1 | N/A | 10 | 200 |
|
3600 | 140 (60) /-20(-29) | 35 | N/A | ||
110-TS | 1 | N/A | 10 | 200 |
|
3600 | 140 (60) /-20(-29) | 35 | N/A | ||
110-TL | 1 | N/A | 10 | 200 |
|
1200 | 140 (60) /-20(-29) | 10 | N/A | ||
105 * | 1 | N/A | 4 | 200 |
|
7500 | 212 (100) /45(7) | <10 | N/A | ||
105-SS * | 1 | N/A | 4 | 200 |
|
7500 | 212 (100) /45(7) | <10 | N/A |
110-T & 105 Accessories |
5920 one contact receptacle |
5921-S one contact receptacle w/ 6" wire |
5952 one contact cap w/solder lug |
Receptacle used for mounting to rotating device. |
110-T & 105 Connections |
Note: The metal receptacle used for mounting is electrically conductive. Therefore, if desired, it can be used as the electrical connection between the 110 and the rotating member of the machine using Part #5920. However, if an insulated mounting at the rotating member is being used, then Part #5921-S with six inch wire lead is used for the electrical connection. |
110-T & 105 Suggested Mounting Methods | ||||||||||||||||||||
|
||||||||||||||||||||
|
||||||||||||||||||||
Installation Notes:
|
Model 1250 One Conductor, 250 Amp
|
||
4 jam nuts included Boot kit available Available in metric thread (1250-M) Available with stainless steel ball bearing (1250-SS) (recommended for wet or corrosive environments) Available with stainless steel body and bearing (1250-SX / 1250-MSX) (recommended for wet or corrosive environments) |
Model No. | Terminals | Voltage AC/DC |
Amp Rating @240VAC |
Max. Freq. MHz |
Contact Resistance |
Max. RPM |
Temp Max. F (C) / Min. F (C) |
Rotation Torque (gm-cm) |
Circuit Separation |
1250 | 1 | N/A | 250 | 200 |
|
1200 | 140 (60) /-20(-29) | 250 | N/A | ||
1250-SS | 1 | N/A | 250 | 200 |
|
1200 | 140 (60) /-20(-29) | 250 | N/A | ||
1250-M | 1 | N/A | 250 | 200 |
|
1200 | 140 (60) /-20(-29) | 250 | N/A | ||
1250-MS | 1 | N/A | 250 | 200 |
|
1200 | 140 (60) /-20(-29) | 250 | N/A | ||
1250-SX | 1 | N/A | 250 | 200 |
|
1200 | 140 (60) /-20(-29) | 250 | N/A | ||
1250-MSX | 1 | N/A | 250 | 200 |
|
1200 | 140 (60) /-20(-29) | 250 | N/A |
1250 Accessories |
57125 Book Kit for dust and splash protection IP51 |
||
1250 Connections |
1250 Suggested Mounting Methods | ||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||
Installation Notes:
|