Greatest reference in our business is our successful past

C137C/48EV DOĞRU AKIM (DC) KONTAKTÖR

C137C/48EV  DOĞRU AKIM (DC) KONTAKTÖR
C137C/48EV Contactor for battery voltages Single-pole NO contactor for 40 A DC and coil voltage 24 V with coil suppression. For ordering contactors with other existing coil voltages or with auxiliary contact click on "Ordering code" on the right hand side. Features Compact design Double-break contacts Wide coil tolerance Replaceable main contacts Version with magnetic blowout Standards: IEC 60077, EN 50124 Weight: 220 g Technical Data Max. rated voltage of main contacts UN 120 V Rated insulation voltage Ui at PD3 160 V Conventional thermal current Ith 40 A Making capacity (resistive load τ = 0 msec.) 400 A Breaking capacity (τ < 1msec.) Contact type NO, single pole Coil voltage 24 V Coil tolerance -30% ... +25% coil voltage Coil suppression Varistor Nominal coil power 8 W Operating mode monostable Auxiliary contact Microswitch (to be ordered separately) Contact material of main contact Ag Sn O2 Protection degree IP00 Mechanical endurance 3 million operating cycles Electrical endurance >100,000 op. cycles UN, Ith, τ<1 msec. Vibration Shock Catergory 1, class B (IEC 61373) Ambient air temperature range -25°C ... +70°C Storage temperature range -40°C ... +85°C More Info Price

C163 C/24BD-J1 DOĞRU AKIM (DC) KONTAKTÖR

C163 C/24BD-J1  DOĞRU AKIM (DC) KONTAKTÖR
C163 C/24BD-J1 Contactor for battery voltages, bistable version Bistable single-pole NO contactor for 80 A DC and coil voltage 24 V with coil suppression. With the bistable type of contactor the change of state: „contact normally open“ and „contact closed“ is triggered by a short switching impulse of only 50 msec. duration. Both normal and total travel position are stable. That is to say that no coil voltage is needed for either position. The benefit of this drive concept: No energy consumption during continuous duty! Bistable contactors are especially suitable for use as deep discharge protection of batteries for uninterruptible power supply (UPS). For ordering contactors with other existing coil voltages or with auxiliary contact click on "Ordering code" on the right hand side. Features Compact design No coil power in open and closed position Conventional thermal current Ith up to 100 A DC Special designs up to 150 V DC Various coil voltages available Replaceable main contacts Version with blowout magnets Standards: IEC 60947, EN 50124 Weight: 800 g Technical Data Max. rated voltage of main contacts UN 110 V Rated insulation voltage Ui at PD3 630 V Conventional thermal current Ith 80 A Making capacity (resistive load τ = 0 msec.) 800 A Breaking capacity (τ < 1msec.) Contact type NO, 1 pole Coil voltage 24 V Coil tolerance +25% ... -40% Coil suppression Diode Nominal coil power 18 W Operating mode bistable Auxiliary contact Microswitch (to be ordered separately) Contact material of main contact Ag Cd O Protection degree IP00 Mechanical endurance 3 million operating cycles Electrical endurance >100,000 op. cycles UN, Ith, τ<1 msec. Vibration Shock Catergory 1, class B (IEC 61373) Ambient air temperature range -25°C ... +70°C Storage temperature range -40°C ... +85°C More Info Price

C163 C_60BX-U1 DOĞRU AKIM (DC) KONTAKTÖR

C163 C_60BX-U1  DOĞRU AKIM (DC) KONTAKTÖR
C163C/60BX-U1 Contactor for battery voltages, bistable version Bistable single-pole NO contactor for 80 A DC and coil voltage 60 V without coil suppression. With the bistable type of contactor the change of state: „contact normally open“ and „contact closed“ is triggered by a short switching impulse of only 50 msec. duration. Both normal and total travel position are stable. That is to say that no coil voltage is needed for either position. The benefit of this drive concept: No energy consumption during continuous duty! Bistable contactors are especially suitable for use as deep discharge protection of batteries for uninterruptible power supply (UPS). Features Compact design No coil power in open and closed position Conventional thermal current Ith up to 100 A DC Special designs up to 150 V DC Various coil voltages available Replaceable main contacts Version with blowout magnets Standards: IEC 60947, EN 50124 Weight: 800 g Technical Data Max. rated voltage of main contacts UN 110 V Rated insulation voltage Ui at PD3 630 V Conventional thermal current Ith 80 A Making capacity (resistive load τ = 0 msec.) 800 A Breaking capacity (τ < 1msec.) Contact type NO, 1 pole Coil voltage 60 V Coil tolerance +25% ... -40% Coil suppression none Nominal coil power 18 W Operating mode bistable Auxiliary contact Microswitch (to be ordered separately) Contact material of main contact Ag Cd O Protection degree IP00 Mechanical endurance 3 million operating cycles Electrical endurance >100,000 op. cycles UN, Ith, τ<1 msec. Vibration Shock Catergory 1, class B (IEC 61373) Ambient air temperature range -25°C ... +70°C Storage temperature range -40°C ... +85°C More Info Price

C163C/48EV DOĞRU AKIM (DC) KONTAKTÖR

C163C/48EV DOĞRU AKIM (DC) KONTAKTÖR
C163 C/ 48EV Contactor for battery voltages Single-pole NO contactor for 80 A DC and coil voltage 48 V with coil suppression. Features Compact design Double-break contacts Wide coil tolerance Replaceable main contacts Version with magnetic blowout Standards: EN 60947, EN 50124, IEC 60077-1 Weight: 550 g Technical Data Max. rated voltage of main contacts UN 110 V Rated insulation voltage Ui at PD3 160 V Conventional thermal current Ith 80 A Making capacity (resistive load τ = 0 msec.) 800 A Breaking capacity (τ < 1msec.) Contact type NO, single pole Coil voltage 48 V Coil tolerance +25% ... -30% Coil suppression Varistor Nominal coil power 18 W Operating mode monostable Auxiliary contact silver plated contacts (not serially) Contact material of main contact Ag Cd O Protection degree IP00 Mechanical endurance 3 million operating cycles Electrical endurance >100,000 op. cycles UN, Ith, τ<1 msec. Vibration Shock Catergory 1, class B (IEC 61373) Ambient air temperature range -25°C ... +70°C Storage temperature range -40°C ... +85°C More Info Price

C165C/48EV DOĞRU AKIM (DC) KONTAKTÖR

C165C/48EV DOĞRU AKIM (DC) KONTAKTÖR
C165C/48EV Contactor for battery voltages Single-pole NO contactor for 220 A DC and coil voltage 48 V with coil suppression. Features Compact design Double-break contacts Wide coil tolerance Replaceable main contacts Version with magnetic blowout Standards: EN 50124, IEC 60077-1 Weight: 1900 g Technical Data Max. rated voltage of main contacts UN 110 V Rated insulation voltage Ui at PD3 160 V Conventional thermal current Ith 220 A Making capacity (resistive load τ = 0 msec.) 2000 A Breaking capacity (τ < 1msec.) Contact type NO, single pole Coil voltage 48 V Coil tolerance +25% ... -30% Coil suppression Varistor Nominal coil power 27 W Operating mode monostable Auxiliary contact Microswitch (to be ordered separately) Contact material of main contact Ag Cd O Protection degree IP00 Mechanical endurance 3 million operating cycles Electrical endurance >100,000 op. cycles UN, Ith, τ<1 msec. Vibration Shock Catergory 1, class B (IEC 61373) Ambient air temperature range -25°C ... +70°C Storage temperature range -40°C ... +85°C More Info Price

C195S/48EV DOĞRU AKIM (DC) KONTAKTÖR

C195S/48EV  DOĞRU AKIM (DC) KONTAKTÖR
C195S/48EV Contactor for battery voltages Single-pole NO contactor for 250 A DC and coil voltage 24 V with coil suppression. For ordering contactors with other existing coil voltages or with auxiliary contact click on "Ordering code" on the right hand side. Features Compact design Double-break contacts Wide range of coil voltage tolerance Replaceable main contacts Version with blowout magnets Standards: IEC 60077; EN 50124 Weight: 1600 g Technical Data Max. rated voltage of main contacts UN 220 V Rated insulation voltage Ui at PD3 1000 V Conventional thermal current Ith 250 A Making capacity (resistive load τ = 0 msec.) 2500 A Breaking capacity (τ < 1msec.) Contact type NO, single pole Coil voltage 24 V Coil tolerance -30% ... +25% Coil suppression Varistor Nominal coil power 25 W Operating mode Auxiliary contact 2 microswitches (to be ordered separately) Contact material of main contact Ag Cd O Protection degree IP00 Mechanical endurance 3 million operating cycles Electrical endurance Vibration Shock Ambient air temperature range -25°C ... +50°C Storage temperature range -40°C ... +85°C More Info Price

C200/150 24FV-VG1 DOĞRU AKIM (DC) KONTAKTÖR

C200/150 24FV-VG1     DOĞRU AKIM (DC) KONTAKTÖR
C200/150 24FV-VG1 Contactor for battery voltages Single-pole NO contactor for 150 A DC operating current and coil voltage 24 V with coil suppression Fitted with magnetic blowout option the C200/150 is suitable for use as main or auxiliary contactor. Its DC coil is characterized by extra wide coil tolerance as required for batteries in backup systems of uniterruptible power supply (UPS) and fixed parts of mobile networks. For ordering contactors with other existing coil voltages or with auxiliary contact click on "Ordering code" on the right hand side. Features Rugged, compact design Cadmium-free, double-break contacts Wide range of coil voltage tolerance Option of magnetic blowout Standards: EN 60947-1, EN 1175-1 Weight: <800 g Technical Data Max. rated voltage of main contacts UN 48 V Rated insulation voltage Ui at PD3 150 V Conventional thermal current Ith 150 A Making capacity (resistive load τ = 0 msec.) 1000 A Breaking capacity (τ < 1msec.) 60 V: 200 A ( w/o blowout) / 500 A (with blowout) Contact type NO, 1 pole Coil voltage 24 V Coil tolerance -10% ... +25% coil voltage Coil suppression Varistor Nominal coil power Operating mode monostable Auxiliary contact Microswitch, SPDT Contact material of main contact Ag Sn O2 Protection degree IP00 Mechanical endurance >1 million operating cycles Electrical endurance >100,000 op. cycles UN, Ith, τ<1 msec. Vibration Shock 25 g (6 msec., half sinus) Ambient air temperature range -25°C ... +60°C Storage temperature range -40°C ... +85°C More Info Price

C200/250 24FV-VG1 DOĞRU AKIM (DC) KONTAKTÖR

C200/250 24FV-VG1    DOĞRU AKIM (DC) KONTAKTÖR
C200/250 24FV-VG1 Contactor for battery voltages Single-pole NO contactor for 250 A DC operating current and coil voltage 24 V with coil suppression Fitted with magnetic blowout option the C200/250 is suitable for use as main or auxiliary contactor. Its DC coil is characterized by extra wide coil tolerance as required for batteries in backup systems of uniterruptible power supply (UPS) and fixed parts of mobile networks. For ordering contactors with other existing coil voltages or with auxiliary contact click on "Ordering code" on the right hand side. Features Rugged, compact design Cadmium-free, double-break contacts Wide range of coil voltage tolerance Option of magnetic blowout Standards: EN 60947-1, EN 1175-1 Weight: <1.5 kg Technical Data Max. rated voltage of main contacts UN 48 V Rated insulation voltage Ui at PD3 150 V Conventional thermal current Ith 250 A Making capacity (resistive load τ = 0 msec.) 1600 A Breaking capacity (τ < 1msec.) 60 V: 300 A (w/o blowout) 1300 A (with blowout) Contact type NO, 1 pole Coil voltage 24 V Coil tolerance -10% ... +25% coil voltage Coil suppression Varistor Nominal coil power <25 W cold coil <18 W warm coil Operating mode monostable Auxiliary contact Microswitch, SPDT Contact material of main contact Ag Sn O2 Protection degree IP00 Mechanical endurance >1 million operating cycles Electrical endurance >100,000 op. cycles UN, Ith, τ<1 msec. Vibration Shock 25 g (6 msec., half sinus) Ambient air temperature range -25°C ... +60°C Storage temperature range -40°C ... +85°C More Info Price

C200/400 24FV-VG1 DOĞRU AKIM (DC) KONTAKTÖR

C200/400 24FV-VG1  DOĞRU AKIM (DC) KONTAKTÖR
C200/400 24FV-VG1 Contactor for battery voltages Single-pole NO contactor for 400 A DC operating current and coil voltage 24 V with coil suppression The C200/400 is suitable for use as main or auxiliary contactor. Its DC coil is characterized by extra wide coil tolerance as required for batteries in backup systems of uniterruptible power supply (UPS) and fixed parts of mobile networks. For ordering contactors with other existing coil voltages or with auxiliary contact click on "Ordering code" on the right hand side. Features Rugged, compact design Cadmium-free, double-break contacts Wide range of coil voltage tolerance Standards: EN 60947-1, EN 1175-1 Weight: <1.6kg Technical Data Max. rated voltage of main contacts UN 48 V Rated insulation voltage Ui at PD3 150 V Conventional thermal current Ith 400 A Making capacity (resistive load τ = 0 msec.) 1000 A Breaking capacity (τ < 1msec.) 60 V: 500 A (without blowout) Contact type NO, 1 pole Coil voltage 24 V Coil tolerance -10% ... +25% coil voltage Coil suppression Varistor Nominal coil power <19 W cold coil <16 W warm coil Operating mode monostable Auxiliary contact Microswitch, SPDT Contact material of main contact Ag Sn O2 Protection degree IP00 Mechanical endurance >1 million operating cycles Electrical endurance >100,000 op. cycles UN, Ith, τ<1 msec. Vibration Shock 25 g (6 msec., half sinus) Ambient air temperature range -25°C ... +60°C Storage temperature range -40°C ... +85°C More Info Price

SCHALTBAU MARKASINA A?T ?R?N GRUPLARI

Compact contactors for 1000 V DC and 1500 V AC resp
Compact contactors for 1000 V DC and 1500 V AC resp
DC contactors for battery-powered vehicles
DC contactors for battery-powered vehicles
DC contactors for railway applications
DC contactors for railway applications
DC contactors for uninterruptible power supplies (UPS)
DC contactors for uninterruptible power supplies (UPS)
Industrial connectors
Industrial connectors
Snap-action switches
Snap-action switches