Innovative measuring device with laser technology to monitor small to medium dust emission according to the new European regulations
|
Features |
|
Integrated display: Measuring value, threshold value, parameter in probe |
|
In-situ measuring procedure with continuous measurement |
|
High sensitivity |
|
Easy installation on one side of the duct |
|
Can also be deployed in thick-walled stone/insulated channels | |
Long lifetime, as there are no moving parts inside the duct | |
Hermetically sealed electronic housing against exhaust gas | |
Parameterisation and operation with keyboard plus easily readable display directly on device or via bus interface | |
Automatic function test with soiling correction | |
Two analog outputs with adjustable measuring ranges | |
Automatic switching of measuring ranges according to 17. BImSchV. | |
Applications |
|
Power stations | |
Cement plants, the metallurgy and wood industries, chemical industry etc. | |
Waste incineration plants | |
Monitoring of dust filter plants. |
|
|
measurements |
dust concentration |
measuring ranges |
0–10 mg/m3 ... 0–200 mg/m3 1) |
measuring principle |
forward scattering |
flue gas temperature |
above dew point up to 220 °C |
flue gas pressure |
-50 up to+10 hPa |
duct diameter |
1–8 m |
ambient temperature |
-20 up to +50°C |
protection |
IP65 |
measuring outputs |
2 x 0 / 4–20 mA / 500 Ohm, |
digital outputs |
4 relay outputs, programmable, |
digital inputs |
2 potential free inputs, programmable |
accuracy |
<2% of measuring range |
detection limit |
<2% of measuring range |
reference point drift |
<2% of measuring range/month |
zero point drift |
<2% of measuring range/month |
supply voltage |
85–264 VAC, 47–63 Hz, 50 VA |
dimensions (H x W x D) |
measuring lance: |
weight |
measuring lance: 7 kg |
remarks |
1) after gravimetric calibration |
purge air supply |
integrated into supply unit |