Continuous monitoring of flow velocity and direction |
Features |
|
Non-contact ultrasonic monitoring according to the principle of transit time differential |
|
Automatic zero-point and span test |
|
Minimal maintenance costs |
|
Rugged V4A stainless steel housing, IP65 enclosure rating |
|
Complies with environmental testing according to IEC 68-1 |
|
No influence of smoke on the system in case of fire. |
|
|
measuring principle |
ultrasonic transition time |
measuring path |
10 m, optional up to 20 m |
measuring principle |
Ultraschall-Laufzeitverfahren |
installation angle |
30° up to 60°, typical 45° |
measuring range |
-20 up to +20 m/s |
error limit |
2% of full range |
output signal |
velocity 4-20 mA / 500 Ohms, |
status contacts |
- limit exceedence, - error, - maintenance |
integration time | 1-180 s |
temperature range | -20 up to 55°C |
ptotection | IP65 |
supply voltage | 115/230 V, ±10%, 50/60 Hz, 50 VA |
electrical connection sensor / evaluation unit | 15 m cable length as standard, other length on request |
housing sensor unit | stainless steel |
Weight | 2 kg per sensor unit |
housing evaluation unit | Wandgehäuse, 265x300x240mm (LxWxH) |
Bus-Sensors |
|
D-G 102 PM - CO-sensor |
|
D-G 102 PM - NO-sensor |
|
D-G 102 PM - NO2-sensor |
|
|
measuring range |
0...300 ppm CO |
response time t90 |
<20 s |
Max. perm. ambient temperature |
-20....+50°C |
Non-contact, continuous monitoring of visibility levels |
Features |
|
Use of autocollimation (double-pass) principle doubles the sensitivity of the monitor |
|
Suitable for cold-fire detection |
|
Easy installation and menu-driven operation |
|
Window contamination correction performed automatically |
|
Entspricht den Umweltprüfungen nach IEC 68-1 |
|
Long maintenance intervals | |
Rugged V4A stainless steel housing, IP65 enclosure rating | |
Complies with environmental testing according to IEC 68-1 | |
Profibus dp (option) |
|
|
measuring principle |
Transmission |
path length |
up to 12 m |
light source |
SWBD Super Wide Band Diode |
measuring range |
0 - 15/km |
error limit |
<2% of measuring range |
integration time |
5 -1800 s |
max. perm. ambient temperature |
-20 up to55°C |
max. deviation from optical axis |
0.35° |
output signal |
0-20 mA/500 Ohm, optional Modbus |
6 status contacts |
- limit exceedence |
conformity |
IEC 68-1 |
MTBF |
approx. 10.000 Std. |
supply voltage |
95 - 264 V, 48 - 62 Hz |
power consumption |
approx. 30 VA |
protection |
IP65 |
housing |
V4A stainless steel (1.4571) |
weights |
measuring head: approx. 10 kg |