Measuring system to measure flow rate in dry emissions with a probe using the differential pressure principle |
Features |
|
Measurement of emission speed |
|
Calculation of volume flow at standard conditions with the evaluation unit D-FL 100-10 (optional) |
|
Adjustable parameters |
|
Automatic back purging device (optional) |
|
Versions with or without counter-support and for point measurement |
|
Applications |
|
Volume flow measurement at high temperatures |
|
Plants with large or small flue cross-sections |
|
Volume flow measurement at high pressure |
|
|
measurements |
flue gas velocity, volume flow 1) |
measuring ranges |
0–3000000 m3/h / 3–40 m/s |
measuring principle |
differential pressure |
flue gas temperature |
above dew point up to 400°C, optional up to 800°C |
flue gas pressure |
-700 up to 1000 hPa, optional higher |
duct diameter |
0.4–8 m |
ambient temperature |
-20 up to +50°C |
protection |
IP65 |
measuring outputs |
0 / 4–20 mA / 500 Ohm |
digital outputs |
3 relay outputs, |
digital inputs |
- |
accuracy |
<2% of measuring range |
detection limit |
<3 m/s |
reference point drift |
<0,5% of measuring range/month |
zero point drift |
<0,5% of measuring range/month |
supply voltage |
14–45 VDC |
dimensions |
probe: 380 x 160 x (300 + probes length) mm |
weight |
32 kg + 6,8 kg/m probes length |
purge air supply |
ggf. 6–8 bar für Rückspülung |
remarks |
1) optional pressure- and temperature correctionr |
Measuring system for ultra-sonic measuring of velocity and volume flow, especially for wet and aggressive smoke emissions (waste incineration).
Measuring system for ultra-sonic measuring of velocity and volume flow, especially for wet and aggressive smoke emissions (waste incineration) |
Features |
|
In-situ measuring method |
|
Measurement possible below dew point and for high dust concentrations |
|
Continuous measurement of normal volume flow and gas velocity |
|
Automatic zero point and reference point control |
|
Direct connection for temperature and pressure correction |
|
Parameter input via keyboard or PC |
|
Continuous temperature measuring |
|
Applications |
|
Volume flow measuring at low speeds |
|
Plants with damp and/or aggressive exhaust gas, e.g. in waste incineration plants. |
|
Volume flow measurement at high dust content |
|
|
measurements |
flue gas velocity, volume flow 1), temperature |
measuring ranges |
0–3000000 m3/h / 0–40 m/s |
measuring principle |
acoustic propagation delay |
flue gas temperature |
0–200°C, optional higher |
flue gas pressure |
-50 up to +20 hPa, optional higher |
duct diameter |
0,7–10 m, temperature dependent |
ambient temperature |
-20 up to +50°C |
protection |
IP65 |
measuring outputs |
2 x 0 / 4–20 mA / 500 Ohm, |
digital outputs |
3 relay outputs, |
digital inputs |
- |
accuracy |
<2% of measuring range |
detection limit |
<0.3% of measuring range |
reference point drift |
<0.3% of measuring range/month |
zero point drift |
<0.2% of measuring range/month |
supply voltage |
115 / 230 VAC, 50 / 60 Hz, 50 VA |
dimensions |
standard measuring head: 190 Ø x 570 mm |
weight |
17 kg |
remarks |
1) optional pressure and temperature correction |
purge air supply |
|
purge air quantity |
approx. 80 m3/h |
supply voltage |
115 / 230 V, 50 / 60 Hz, |
dimensions (H x B xT |
350 x 550 x 500 mm |
protection |
IP54 |