Greatest reference in our business is our successful past

ELECTRONIC DC VOLTAGE RELAY MODEL DOVR

ELECTRONIC DC VOLTAGE RELAY  MODEL DOVR

ELECTRONIC DC VOLTAGE RELAY 

DOVR  MODEL

Compact Design
Definite Trip Time-current Characteristic
Trip & Run Indication(LED)
Solid State DC Over-voltage/Undervoltage Protection
 
 
 
Protective Item

Trip Time

Over-voltage

0.2~30 sec

   
 
 
Model
DC Over-voltage

Voltage Setting

Type

Voltage Setting Range

10

1-10V

30

3-30V

110
10-110V
220
20-220V

Others

Option

Trip Time Setting
Trip Delay
O-TIME
0.2 - 30ÃÊ
Reset
M
Manual
A
Auto (option)

Auxiliary Relay

Mode/Rating
1-SPDT(1C)

3A/250VAC, Resistive

Status
R Type
Normally De-energized
Control Voltage
220
110/220VAC, 50/60Hz
Others
Other Voltage Option
Mounting
Panel
   
 
 
 
 

More Info Price

ELECTRONIC DC VOLTAGE RELAY DUVR

ELECTRONIC DC VOLTAGE RELAY DUVR

ELECTRONIC DC VOLTAGE RELAY

DUVR model

Compact Design 
■ Definite Trip Time-current Characteristic
■ Trip & Run Indication(LED)
■ Confirm actual current and precise setting possible as it has Voltage Meter.
■ Solid State DC Over-voltage/Undervoltage Protection

Protection


Protective Item

Trip Time

DUVR
Under-voltage
0.2~30 sec
 
 
Model
DC Undervoltage

Voltage Setting

Type

Voltage Setting Range

10
-

30

3-30V
110
20-110V
220
30-220V

Others

Auto(Option)

Trip Time Setting
Trip Delay
O-TIME
0.2 - 30ÃÊ
Reset
M
Manual(Instantaneous)/Electrical Reset
A
Auto(Option)

Auxiliary Relay

Mode/Rating
1-SPDT(1C)

3A/250VAC Resistive

Status
R Type
Normally De-energized
Control Voltage
220
110/220VAC, 50/60Hz
Others
Other Voltage Option
Mounting
Panel
 

 

 

More Info Price

ELECTRONIC DC VOLTAGE RELAY MODEL DVR

ELECTRONIC DC VOLTAGE RELAY MODEL DVR

 ELECTRONIC DC VOLTAGE RELAY

MODEL DVR
MCU( Microprocessor Control Unit ) Based
DC Motor/DC Device Protection
Separate Setting for Over-voltage and Undervoltage
Line Voltage Indicative Function(FND)
Digital Setting/Trip Cause Indication & troubleshooting
Auto Reset/Reset Time Setting
Confirm Setting Value/TEST Function
No Volt Release Function( Fail-safe Operation)Selectable
 
 
Protective Item

Trip Time

Over-voltage

0.5~25 sec

Under-voltage
0.5~25 sec
   
 
 
Model
DVR
Setting Range
110VDC
220VDC

Over-voltage

OVR

110 - 160V

220 - 320V
Under-voltage
UVR

60 - 110V

160 - 240V
Trip Time

O-TIME

0.5 - 25 sec

Reset Time
R-TIME
0.5 - 25 sec
Power Supply
Voltage
24
24VAC/DC
220
85V - 250VAC/DC
Frequency
50/60Hz
Reset
Manual/Electrical/Auto
Mounting
35mm DIN-Rail/Panel
   
 
 
 
 

More Info Price

samwha EOCR MARKASINA A?T ?R?N GRUPLARI

CURRENT TRANSFORMERS(CT)
CURRENT TRANSFORMERS(CT)
ELECTRONÄ°C AC CURRENT RELAY
ELECTRONÄ°C AC CURRENT RELAY
ELECTRONÄ°C AC VOLTAGA RELAY
ELECTRONÄ°C AC VOLTAGA RELAY
ELECTRONÄ°C DC CURRENT RELAY
ELECTRONÄ°C DC CURRENT RELAY
ELECTRONIC DC VOLTAGE RELAY
ELECTRONIC DC VOLTAGE RELAY
NEW PRODUCTS
NEW PRODUCTS
OTHER PROTECTÄ°ON-MONÄ°TORING DEVÄ°CE
OTHER PROTECTÄ°ON-MONÄ°TORING DEVÄ°CE