DC-JA7 |
|
Easy to see! |
Kinds |
Addition type total counter |
|
Model No. |
DC-JA7-AW |
DC-JA7-DW |
Power source |
100 to 240VAC(50/60Hz) |
12 to 24VDC(Ripple 20% or less) |
Fluctuation range |
85 to 250VAC |
12 to 24VDC±10% |
Power consumption |
1.2VA(when 240VAC) |
0.7W(when 24VDC) |
Front size |
24×48mm |
|
Number of digit |
7 digits(8 digits with overflow display) |
|
Display |
7-segment LCD(LED backlight), height 9mm, width 2.95mm |
|
Memory function |
EEP-ROM(Re-writing 0.1 million times or more) |
|
Counting speed |
30Hz/1kHz changeover, |
|
Input signal |
Contact and open-collector(flow current when short-circuited : approx. 4mA) |
|
Ambient temperature/humidity |
-10 to +50 degrees C(-25 to +55 degrees Cwhen stored), 35 to 85%RH |
|
Insulation resistance |
100MΩ or more(500VDC megger) between conducting terminal and uncovered non-charged metal |
|
Withstand voltage |
2000VAC/min. between conducting terminal and uncovered non-charged metal |
|
Noise resistance |
Square-wave noise by noise simulator(Rising 1nsec, width 1µsec) |
|
Static electricity |
10kV but 8kV when malfunction |
|
Vibration resistance |
Double amplitude 4mm, 16.7Hz (Malfunction : Double amplitude 0.5mm, 10 to 55Hz), each 1 hour in X, Y and Z direction |
|
Impact resistance |
294m/s2( Malfunction : 98m/s2) each 3 time in X, Y and Z direction |
|
Starting time when Power-ON |
2sec or less |
|
Protective structure |
IP66(Only front panel : must be using rubber packing) |
|
Case material |
Polycarbonate |
|
Weight |
Approx. 70g |
|
Attachment |
Mounting hook, rubber packing |
Counter
Panel-cut dimension
DC-JA(AC power) |
DC-JA(DC power) |
[Caution]
* Use the solderless terminal for M3.
* Use 2-core shield wire or metal wire tube and make it as short as possible. Don't make parallel wiring with power cable or high voltage cable etc.
* Counting input can't be accepted for 2sec after putting power source in.
Input(count/reset)
[Caution]
* Each input circuit of DC-JA series is common use for contact and transistor. Flow current from the counter is approx. 4mA. Use the relay for little current in case of contact input.
More Info Price
DC-JM |
|
12 pcs of counters are built-in |
Kind |
Increment type preset counter |
|||
Model No. |
DC-JM4-AW |
DC-JM4-DW |
DC-JM6-AW |
DC-JM6-DW |
Power source |
100 to 240VAC |
24VDC |
100 to 240VAC |
24VDC |
Fluctuation range |
±10% when 24VDC, 85 to 250VAC |
|||
Power consumption |
4VA*1(when 240VAC) |
1W(when 24VDC) |
4VA*1(when 240VAC) |
1W(when 24VDC) |
Built-in counter numbers |
12 |
|||
Preset |
1 preset |
|||
Output numbers |
1 output(12 pcs of counter, OR output) |
|||
Divider function |
1/100 |
|||
Memory function |
EEP-ROM(Re-writing 0.1 million times or more) |
|||
Counting speed |
Changeover for 30Hz/5kHz |
|||
Display |
7-segment LCD(LED back-light) |
|||
Input signal |
Contact or open-collector |
|||
Output |
Transistor output(NPN open-collector) : 100mA or less, 40V or less |
|||
Control output |
Transistor output(NPN open-collector) : 100mA or less, 40V or less |
|||
Power source for sensor |
12VDC, 50mA*2 |
12VDC, 50mA*2 |
*1 It includes external power source.
*2 In case of using 120VAC or less as power source, possible to supply 100mA outside
Counter
60→48 frame(GZ00003)
Use this frame when using DC-J instead of our counter with 60×60 such as DC-NXB, DC-S series.
AC Power |
DC Power |
Note)Power source for sensor isn't provided. |
(Caution)
1. | Don't use empty terminal as relay terminal. |
2. | Each input for counting and reset is common use for contact and transistor. Make a wiring with 2-core shield wire and metal as short as possible. Also, don't make a wiring with power and high voltage line etc. |
3. | Use solderless terminal for M3. |
4. | DC-J doesn't operate for approx. 2.5 sec after putting power source in. |
Input(counting/counter No.choice) |
Transistor output |
|
|
DC-M |
LED display DIN size |
Easy operation, clear display & easy pre-set |
72×72mm type
Type |
Increment/decrement type total counter |
Increment/decrement type preset counter |
Model No. |
DC-MA6-D |
DC-MB6-D |
Display |
Red LED 7-segment LED(Height10mm, width5.7mm), Range: 999999 to -99999 (Zero-suppress) |
|
Number of digit |
6 digits |
|
Power source |
100 to 240VAC(50/60Hz) |
|
Fluctuation range |
-15% to +10% |
|
Power consumption |
Approx. 4.5VA(when 240VAC) |
|
Counting |
Contact/transistor open-collector input : Counting when OFF→ON, voltage input: Counting when “L”→“H” |
|
Preset |
1 |
|
Preset method |
Digital switch for each digit |
|
Counting speed |
30Hz: Min. signal width 16.7msec, make-ratio 1:1 |
|
Counting prohibited |
Prohibited when ON("H" level in case of voltage input)Response time: 16msec or less(when 30Hz), 100μsec or less(when 5kHz) |
|
Counting/ reset/counting prohibited input |
Contact/transistor open-collector input Impedance(ZON): 1kΩ or less when ON(Short-circuit), Impedance(ZOFF): 5kΩ or more when OFF(Opened) |
|
Control output operation |
Self-holding operation: It operates when preset value and returns by reset |
|
Power source for sensor |
12VDC(+10%, -10%), 100mA(Ripple 5% or less) |
|
Ambient temperature, humidity |
-10 degrees C to +45 degrees C(-20 degrees C to +55 degrees C when stored) 45 to 85%RH |
|
Memory time against power failure |
Memory time/once: approx. 10 years, memory numbers: 0.1 million times |
|
Case |
Case: ABS resin, dust-proof cover: polycarbonate |
|
Attachment |
Dust-proof cover, fitting metal |
72×144mm type
Type |
Increment/decrement type total counter |
Increment/decrement type preset counter |
Increment/decrement type 2-preset counter |
Model No. |
DC-MA6-E |
DC-MB6-E |
DC-MC6-E |
Display |
Red LED 7-segment LED(Height15mm, width8.8mm), Range: 999999 to -99999 (Zero-suppress) |
||
Number of digit |
6 digits |
||
Power source |
100 to 240VAC(50/60Hz) |
||
Fluctuation range |
-15% to +10% |
||
Power consumption |
約4.5VA(when 240VAC) |
||
Counting |
Contact/transistor open-collector input : Counting when OFF→ON, voltage input: Counting when “L”→“H” |
||
Preset |
1 |
2 |
|
Preset method |
Digital switch for each digit |
||
Counting speed |
30Hz: Min. signal width 16.7msec, make-ratio 1:1 |
||
Counting prohibited |
Prohibited when ON("H" level in case of voltage input)Response time: 16msec or less(when 30Hz), 100μsec or less(when 5kHz) |
||
Counting/ reset/counting prohibited input |
Contact/transistor open-collector input Impedance(ZON): 1kΩ or less when ON(Short-circuit), Impedance(ZOFF): 5kΩ or more when OFF(Opened) |
||
Control output operation |
Self-holding operation: It operates when preset value and returns by reset |
||
Power source for sensor |
12VDC(+10%, -10%), 100mA(Ripple 5% or less) |
||
Ambient temperature, humidity |
-10 degrees C to +45 degrees C(-20 degrees C to +55 degrees C when stored) 45 to 85%RH |
||
Memory time against power failure |
Memory time/once: approx. 10 years, memory numbers: 0.1 million times |
||
Case |
Case: ABS resin, dust-proof cover: polycarbonate |
||
Attachment |
Dust-proof cover, fitting metal |
* DC-MOW with BCD read-out output is also lined up. Ask us in details.。
72×72mm type |
|
|
72×144mm type |
|
|
Input/transister output
Contact/transister open-collector input |
Voltage input |
Connection
DC-M_Connection 72×72mm type
Contact/Open-collector input
Note) Count 1 terminal [8] is increment, Count 2 terminal [9] is decrement. In case of 90 phase-difference input, when Count 1 is shifted shifted by 90°, it is increment counting, and when Count 2 is shifted 90°, it is decrement counting.
Note) In case of Total counter, [4] [5] [6] terminal are not used.
Note) FG [3] terminals should be grounded.
DC-M_Connection 2×144mm type
Contact/Open-collector input
Note) Terminals [11] and [18] are connected inside
Note) Count 1 [12] is increment counting and Count 2 [13] is decrement counting. In case of 90°phase-difference input, when Count 1 is shifted by 90°, it is increment counting, and when Count 2 is shited by 90°, it is decrement counting.
Note) In case of total counter, [4] [5] [6] [7] [8] [9] [16] [17] terminals are not used.
Note) In case of preset counter (1 preset type), [4] [5] [6] [16] terminals are not used.
Note) FG ([3] terminal) should be grounded.
Caution note)
* Do not use unused terminal as relay terminal.
* Each input to counting, reset and count prohibition is common use for contact and open-collector. Wire to each input and output terminal 2-core shield wire or metal conduit tube as short as possible. Do not lay the wires close to or parallel to line cable, power cable or high voltage line.
* For connection, use M3 pressure connection terminals.
DC-JB/JC |
|
VARIOUS FUNCTIONS IN DIN SIZE(48×48)! |
Type |
1-preset counter |
2-preset counter |
||||||
Model No. |
DC-JB6 |
DC-JB6 |
DC-JB6 |
DC-JB6 |
DC-JC6 |
DC-JC6 |
DC-JC6 |
DC-JC6 |
Power source |
100 to 240VAC(50/60Hz) |
24VDC(ripple 20% or less) |
100 to 240VAC(50/60Hz) |
24VDC(ripple 20% or less) |
||||
Fluctuation range |
±10% when 24VDC, 85 to 250VAC |
|||||||
Power consumption |
4VA*1(240VAC) |
1W(24VDC) |
5VA*1(240VAC) |
1W(24VDC) |
||||
Number of digit |
6 digits, -99999 to 999999(Total counter : 12 digits) |
|||||||
Memory function |
EEP-ROM(Re-writing 0.1 million times or more) |
|||||||
Counting speed |
Changeover for 30Hz/5kHz |
|||||||
Reset |
External reset, manual reset, automatic reset |
|||||||
Pre-scale |
0.001 to 9.999 |
|||||||
Decimal point position |
Lower 4 digits |
|||||||
Single-shot time |
0.005 to 9.999s |
|||||||
Display |
7-segment LCD(LED back-light) |
|||||||
Input mode |
Changeover for Increment/decrement independence, Phase-difference, Increment, Decrement, Increment/decrement command |
|||||||
Output mode |
Changeover for One-shot return, Self-holding free, One-shot free, Agree free, Comparing free |
|||||||
Output function |
Changeover for standard or digit-up |
Standard/Batch/Prediction |
||||||
Input signal |
Contact or open-collector, Impedance when ON(short-circuit) : 1k ohm or more, Impedance when OFF(short-circuit) : 100k ohm or more, Flowing current when short-circuit : approx. 4mA |
|||||||
Control output |
Transistor output(NPN open-collector) : 100mA or less, 40V or less |
|||||||
Power for sensor |
12VDC, 50mA |
12VDC, 50mA |
*1 It includes external power source.
*2 Only AC power type with 2-preset provides
Counter
60→48 frame(GZ00003)
Use this frame when using DC-J instead of our counter with 60×60 such as DC-NXB, DC-S series.
AC Power |
DC Power |
||
|
Note) Power source for sensor isn't provided. |
|
|
1. |
Don't use empty terminal as relay terminal. |
2. |
Each input for counting and reset is common use for contact and transistor. Make a wiring with 2-core shield wire and metal as short as possible. Also, don't make a wiring with power and high voltage line etc. |
3. |
Use solderlss terminal for M3. |
4. |
Function of output 1 is different between DC-JB and DC-JC. DC-JB : carry output, DC-JC : standard, batch and prediction output(depending on counter mode). Output 2 is standard output for both DC-JB and DC-JC. |
Input(Counting1/Counting2/Reset) |
Transistor output |
|
|