Greatest reference in our business is our successful past

7612

7612
DESCRIPTION CLAPPER SOLENOID OR ACTUATOR (shank on clapper) TYPES : . Clapper solenoid . Actuator :. Clapper solenoid. Actuator POWER REQUIREMENTS Direct current Duty cycle: 100 % , 25 % , 5 % Nominal power: 2,5 W, 6 W, 19 W Alternative current : Duty cycle 100 % , 25 %, 5 % Nominal power 4 VA - - TECHNICAL FEATURES Connection Snap for clips (2,8x0,5 mm) Weight : 45 g. Power supply : 6 to 220 VDC - 6 to 230 VAC More Info Price

7613 Series: Clapper solenoids or actuators

7613  Series: Clapper solenoids or actuators
DESCRIPTION CLAPPER SOLENOID OR ACTUATOR (shank on clapper) TYPES : . Clapper solenoid . Actuator :. Clapper solenoid. Actuator POWER REQUIREMENTS Direct current Duty cycle 100 % 25 % 5 % Nominal power 2,4 W 5,5 W 18,5 W TECHNICAL FEATURES Connection On wires length 80 mm Weight : 40 g. Power supply : 6 to 220 VDC More Info Price

7617

7617
DESCRIPTION CLAPPER SOLENOID OR ACTUATOR (shank on clapper) TYPES : . Clapper solenoid . Actuator POWER REQUIREMENTS Direct current Duty cycle 100 % 25 % 5 % Nominal power 4 W 12 W 40 W Alternative current Duty cycle 100 % 25 % 5 % Nominal power 7 VA - - Weight : 120 g. Power supply : 6 to 220 VDC - 6 to 230 VAC More Info Price

7960

7960
DESCRIPTION VOLTAGE CUT-OFF LATCHING HOLD MAGNET SOLENOID CURRENT : DIRECT - OPERATION : HOLDING Holding of a system in a determined position. Detachment of the counterplate obtained : 1. by cutting off the voltage supply. 2. manually, by pulling a higher force than the holding force. The return to the "hold" position is obtained by bringing back the counter-plate in the initial position. TECHNICAL FEATURES Hold force 1 daN Nominal power at 20°C 1,5 W Connection On wires length 100 mm Weight : 12 g. Power supply : 6 to 48 VDC More Info Price

7961

7961
DESCRIPTION VOLTAGE CUT-OFF LATCHING HOLD MAGNET SOLENOID CURRENT : DIRECT - OPERATION : HOLDING Holding of a system in a determined position. Detachment of the counter-plate obtained : 1. by cutting off the voltage supply 2. manually, by pulling a higher force than the holding force. The return to the "hold" position is obtained by bringing back the counter-plate in the initial position. : DIRECT - : HOLDINGHolding of a system in a determined position.Detachment of the counter-plate obtained :1. by cutting off the voltage supply2. manually, by pulling a higher force than the holding force.The return to the "hold" position is obtained by bringing back the counter-plate in the initial position. TECHNICAL FEATURES Hold force 0,7 daN Nominal power at 20°C 1 W Connection On wires length 100 mm 7961 Weight : 6 g. Power supply : 6 to 24 VDC More Info Price

7964

7964
DESCRIPTION VOLTAGE CUT-OFF LATCHING HOLD MAGNET SOLENOID CURRENT : DIECT - OPERATION : HOLDING Holding of a system in a determined position. Detachment of the counter-plate obtained : 1. by cutting off the voltage supply 2. manually, by pulling a higher force than the holding force. The return to the "hold" position is obtained by bringing back the counter-plate in the initial position. : DIECT - : HOLDINGHolding of a system in a determined position.Detachment of the counter-plate obtained :1. by cutting off the voltage supply2. manually, by pulling a higher force than the holding force.The return to the "hold" position is obtained by bringing back the counter-plate in the initial position. TECHNICAL FEATURES Hold force :40 daN Nominal power at 20°C :5 W Connection :On wires length 150 mm More Info Price

7965

7965
DESCRIPTION VOLTAGE CUT-OFF LATCHING HOLD MAGNET SOLENOID CURRENT : DIRECT - OPERATION : HOLDING Holding of a system in a determined position. Detachment of the counter-plate obtained : 1. by cutting off the voltage supply 2. manually by pulling a higher force than the holding force. Le retour à la position "maintien" s'obtient en ramenant le dispositif à maintenir dans la position initiale. : DIRECT - : HOLDINGHolding of a system in a determined position.Detachment of the counter-plate obtained :1. by cutting off the voltage supply2. manually by pulling a higher force than the holding force.Le retour à la position "maintien" s'obtient en ramenant le dispositif à maintenir dans la position initiale. TECHNICAL FEATURES Hold force :70 daN Nominal power at 20°C: 6,5 W Connection :On wires length 150 mm Weight : 300 g. Power supply : 6 to 220 VDC More Info Price

7973

7973
DESCRIPTION VOLTAGE CUT-OFF LATCHING HOLD MAGNET SOLENOID CURRENT : DIRECT - OPERATION : PORTEUR Holding of a system in a determined position. Detachement of the counter-plate obtained : 1. by cutting off the voltage supply 2. manually, by pulling a higher force than the holding force. The return to the "hold" position is obtained by bringing back the counter-plate in the initial position. : DIRECT - : PORTEURHolding of a system in a determined position.Detachement of the counter-plate obtained :1. by cutting off the voltage supply2. manually, by pulling a higher force than the holding force.The return to the "hold" position is obtained by bringing back the counter-plate in the initial position. TECHNICAL FEATURES Hold force :³ 12 daN Nominal power at 20°:C 5,4 W Connection :On wires length 100 Weight : 150 g. Power supply : 6 to 220 VDC More Info Price

7974

7974
DESCRIPTION VOLTAGE CUT-OFF LATCHING HOLD MAGNET SOLENOID CURRENT : DIRECT - OPERATION : HOLDING Holding of a system in a determined position. Detachment of the counter-plate obtained : 1. by cutting off the voltage supply 2. manually, by pulling a higher force than the holding force. The return to the "hold" position is obtained by bringing back the counter-plate in the initial position. : DIRECT - : HOLDINGHolding of a system in a determined position.Detachment of the counter-plate obtained :1. by cutting off the voltage supply2. manually, by pulling a higher force than the holding force.The return to the "hold" position is obtained by bringing back the counter-plate in the initial position. TECHNICAL FEATURES Hold force :70 daN Nominal power at 20°C :5,8 W Connection : On wires length 100 mm More Info Price

7975

7975
DESCRIPTION VOLTAGE CUT-OFF LATCHING HOLD MAGNET SOLENOID CURRENT : DIRECT - OPERATION : HOLDING Holding of a system in a determined position. Detachment of the counter-plate obtained : 1. bu cutting off the voltage supply 2. manually, by pulling a higher force than the holding force. The return to the "hold" position is obtained by bringing back the counter-plate in the initial position. TECHNICAL FEATURES Hold force 90 daN Nominal power at 20°C 9,6 W Connection On wires length 150 mm Weight : 500 g. Power supply : 6 to 220 VDC More Info Price

7976

7976
DESCRIPTION VOLTAGE CUT-OFF LATCHING HOLD MAGNET SOLENOID CURRENT : DIRECT - OPERATION : HOLDING Holding of a system in a determined position. Detachment of the counter-plate obtained : 1. by cutting off the voltage supply 2. manually, by pulling a higher force than the holding force. The return to the "hold" position is obtained by bringing back the counter-plate in the initial position. TECHNICAL FEATURES Hold force 200 daN Nominal power at 20°C 17 W Connection On wires length 150 mm Weight : 1000 g. Power supply : 6 to 220 VDC More Info Price

7B07X

7B07X
LINEAR MONOSTABLE SOLENOID WITH MAGNETIC LOCKING BY PERMANENT MAGNET POWER REQUIREMENTS : Direct current : 20 W HOLD FORCE thanks to the permanent magnet : 0,48 daN with power supply at nominal voltage. : Direct current : 20 W : 0,48 daN with power supply at nominal voltage. Weight : 34 g. Power supply : 6 to 24 VDC More Info Price

7B08T

7B08T
LINEAR MONOSTABLE SOLENOID WITH MAGNETIC LOCKING BY PERMANENT MAGNET POWER REQUIREMENTS : direct current : 40 W HOLD FORCE thanks to the permanent magnet : 2,4 daN with power supply at nominal voltage. : direct current : 40 W: 2,4 daN with power supply at nominal voltage. Weight : 82 g. Power supply : 6 to 24 VDC More Info Price

7P23

7P23
ELECTRO-AIMANT LINEAIRE AVEC PALIERS POUR APPLICATIONS INTENSIVES MODELES : . Tirant . Poussant . Traversant Weight : 250 g. Power supply : 6 à 220 VDC More Info Price

7P57

7P57
LINEAR SOLENOID WITH GUIDE CLIPS FOR INTENSIVE APPLICATIONS TYPES : . Pull type . Push type . Through type Weight : 750 g. Power supply : 12 to 220 VDC - 12 to 230 VAC More Info Price

7P78

7P78
LINEAR SOLENOID WITH GUIDE CLIPS FOR INTENSIVE APPLICATIONS TYPES : . Pull type . Push type . Through type Weight : 1100 g. Power supply : 12 to 220 VDC - 12 to 230 VAC More Info Price

7P79

7P79
DESCRIPTION "BOOSTER" SOLENOID FOR ADVANCED APPLICATIONS POWER REQUIREMENTS : . On operate power requirement : 160 W . Maximum hold power requirement : 14,5 W PERFORMANCES : . See the curve of on operate stroke performance here-after (hold performance is 6 daN minimum) . The solenoid can be supplied on a permanent basis with, on operate, the same performances as the 5% version solenoid. . 2 TOR inputs can be programmed. :. On operate power requirement : 160 W. Maximum hold power requirement : 14,5 W :. See the curve of on operate stroke performance here-after (hold performance is 6 daN minimum). The solenoid can be supplied on a permanent basis with, on operate, the same performances as the 5% version solenoid.. 2 TOR inputs can be programmed. TECHNICAL FEATURES Connection Power supply : 6,35 clips or wires 150 mm - Control : 2 clips 2,8 or wires Weight : 1100 g. Power supply : 24 or 48 VDC More Info Price

7P99

7P99
LINEAR SOLENOID WITH GUIDE CLIPS FOR INTENSIVE APPLICATIONS TYPES : . Pull type . Push type . Through type :. Pull type. Push type. Through type Weight : 1600 g. Power supply : 12 to 220 VDC - 12 to 230 VAC More Info Price

7R0415

7R0415
DESCRIPTION LINEAR MINIATURE SOLENOID FOR LITTLE MECHANISMS POWER REQUIREMENTS Direct current Duty cycle 100 % , 25 %, 10 % Nominal power 0,8 W - 8 W More Info Price

7R0420

7R0420
LINEAR MINIATURE SOLENOID FOR LITTLE MECHANISMS POWER REQUIREMENTS Direct current Duty cycle 100 %, 25 % , 10 % Nominal power 1,2 W - 12 W More Info Price

7R0520

7R0520
LINEAR MINIATURE SOLENOID FOR LITTLE MECHANISMS POWER REQUIREMENTS Direct current Duty cycle 100%, 25%, 10 % Nominal power 1,6 W - 16 W More Info Price

VEM20E

VEM20E
DESCRIPTION VOLTAGE APPLICATION ELECTROMAGNETIC DOOR HOLDER IN A STEEL BOX TEST REPORTS CNPP N° 95 02 24 AND 95 02 24 A Material generally linked to a fire system which will automatically release the fire doors in case of a fire, by switching the power off. Electromagnetic holder mounted in a metallic box painted with white epoxy, with cabled local release button, protection level IP42, delivered with an equipped magnetic pin (to choose when ordering) : . PME : magnetic pin mounted on a fixed shock-absorbing support for angles < or = 10° - diameter 50 mm - mounting with 4 screws of 5 mm diameter. . PMO : magnetic pin mounted on a rotating shock-absorbing support for angles < or = 60° - diameter 50 mm - mounting with 4 screws of 5 mm diameter. Possibility of passing power supply cables through the 18 mm diameter holes in the bottom of the box. Available in single box version or in the version equipped with door contact (terminals for the door position contact with 5 connection points). The holder under boxes can be directly mounted on the door (screws with 5 mm diameter) or on supports with fixed or adjustable length, painted with white epoxy, for floor or wall mounting : . SSML150 : fixed length 150 mm . SSML250 : fixed length 250 mm . SSML300 : fixed length 300 mm . SSML400 : fixed length 400 mm . SSMT150 : adjustable length from 150 to 250 mm . SSMT250 : adjustable length from 250 to 350 mm . SSMT300 : adjustable length from 300 to 400 mm . SSMT400 : adjustable length from 400 to 500 mm Please contact us for any complementary information. DIMENSIONS DIRECT CURRENT VEM20E - box dimensions VEM20E - side view Weight : 500 g. Power supply : 24 or 48 VDC More Info Price

VEM20R

VEM20R
DESCRIPTION VOLTAGE CUT-OFF ELECTROMAGNETIC HOLDER MOUNTED IN A STEEL BOX TEST REPORTS CNPP N° 95 00 01 AND 95 00 01 B This material is generally linked to a fire system which will automatically release the fire doors in case of a fire, by switching the power off. Holder mounted in a metallic box painted with white epoxy, with cabled local release button, protection degree IP42, delivered with an equipped keeper-plate (to choose when ordering) : . PPE : equipped keeper-plate mounted on a fixed shock-absorbing support for angles < or = 10° - diameter 50 mm / coated with white zinc - Mounted with 4 screws with a 5 mm . PPEO : equipped keeper-plate mounted on a rotating shock-absorbing support for angles < or = 60° - diameter 50 mm - coated with white zinc - mounted with 4 screws with a 5 mm Possibility of passing cables through the holes of 18 mm diameter in the bottom of the box. Available in simple box bersion or in a version equipped with a contact of door position (terminals for the contact of door position with 5 connection points). Boxes can be directly mounted on the element to control (screws with 5 mm diameter) or mounted on supports with fixed or adjustable length, painted with white epoxy, for floor or wall mounting : . SSML150 : fixed length 150 mm . SSML250 : fixed length 250 mm . SSML300 : fixed length 300 mm . SSML400 : fixed length 400 mm . SSMT150 : adjustable length from 150 to 250 mm . SSMT250 : adjustable length from 250 to 350 mm . SSMT300 : adjustable length from 300 to 400 mm . SSMT400 : adjustable length from 400 to 500 mm Weight : 500 g. Power supply : 24 or 48 VDC More Info Price

VEM50R

VEM50R
DESCRIPTION VOLTAGE CUT-OFF ELECTROMAGNETIC HOLDER MOUNTED IN A STEEL BOX TEST REPORTS CNPP N° 95 00 01 AND 95 00 01 B This material is generally linked to a fire system which will automatically release the fire doors in case of a fire, by switching the power off. Holder mounted in a steel box painted with white epoxy, with cabled local release button, protection degree IP 42, delivered with an equipped keeper-plate (to choose when ordering) : PPE : equipped keeper-plate mounted in a fixed shock-absorbing support for angles < or = 10° - diameter 50 mm / coated with white zinc - mounting with 4 screws of 5 mm PPEO : equipped keeper-plate mounted on a rotating shock-absorbing support for angles < or = 60° - diameter 50 mm - coated with white zinc - mounting with 4 screws of 5 mm Possibility of passing cables through the 18 mm diameter holes in the bottom of the box. Available in simple box version or in a version equipped with a contact of door position (terminals for the contact of door position with 5 connection points). Boxes can be directly mounted on the element to control (screws of 5 mm diameter) or mounted on supports with fixed or adjustable length, painted with white epoxy, for floor or wall mounting : . SSML150 : fixed length 150 mm . SSML250 : fixed length 250 mm . SSML300 : fixed length 300 mm . SSML400 : fixed length 400 mm . SSMT150 : adjustable length from 150 to 250 mm . SSMT250 : adjustable length from 250 to 350 mm . SSMT300 : adjustable length from 300 to 400 mm . SSMT400 : adjustable length from 400 to 500 mm Please contact us for any complementary information. DIMENSIONS DIRECT CURRENT VEM50R - box dimension VEM50R - side view TECHNICAL FEATURES Hold force 50 daN Min. effort of detachment None (antiremanent ejector inside) Standard voltages (Nom. Voltage ± 10%) 24 VDC - 48 VDC Nominal power at 20°C 1,2 W Connection Electrical connection with internal terminals equipped with pass-cables. Weight : 500 g. Power supply : 24 or 48 VDC More Info Price

TEC AUTOMATISMES MARKASINA A?T ?R?N GRUPLARI

Flashing relays
Flashing relays
Impulse relays
Impulse relays
Instantaneous relays
Instantaneous relays
Latching relays
Latching relays
Mounting accessories
Mounting accessories
Multifunction relays
Multifunction relays
PROGRAMMABLE CONTROLLERS
PROGRAMMABLE CONTROLLERS
SENSOR
SENSOR
SOCKETS
SOCKETS
SOLENOIDS AND HOLD MAGNETS
SOLENOIDS AND HOLD MAGNETS
TECHNICAL SUPPORT
TECHNICAL SUPPORT
Timer relays
Timer relays
Voltage sensor relays
Voltage sensor relays