If so, then choose the compact RT9 universal relay to supervise both your safety devices and the internal safety of your machinery. In addition, you can select the safety level that is required for each installation. All this is possible due to the RT9 offering the most versatile input option arrangement available on the market. The RT9 can therefore replace many other relays.
Other RT9 options include selection of either manual supervised or automatic resetting. The manual supervised reset can be used for gates and other safety devices that can be bypassed. Automatic reset can be used for small safety hatches, if deemed acceptable from risk assessment.
In addition, the RT9 has a double information output that will indicate e.g. if a gate is open or if the relay needs resetting.
The RT9 uses the latest component technology and modern assembly techniques to ensure a highly cost effective solution.
Choose the RT9 to simplify your safety circuits and reduce your costs
Applications:
Emergency Stops
Light Curtains
Three Position Devices
Interlocked Gates/Hatches
Magnetic Switches
Light Beams
Safety Mats
Contact Strips
Foot-Operated Switches
Features:
Five input options
Single or dual channel input
Manual supervised or automatic reset
Test input for supervision of external contactors
Width 22.5 mm
LED indication of supply, inputs and outputs, short-circuit and low voltage level
2 NO relay outputs
1 changeover relay with a double information output
24 VDC
Quick release connector blocks
Would you like a single safety relay for all your safety applications?
Then choose the RT6 universal relay to supervise both your safety devices and the internal safety of your machinery. In addition you can select the safety level required for each installation. All this is possible because the RT6 has the most versatile input option arrangement available on the market. Many other relays can therefore be replaced by the RT6.
The relay also comes with other options such as manual or automatic reset. Manual supervised reset can be used for gates and other safety devices that can be bypassed. Automatic reset can be used for small hatches, if deemed acceptable from risk assessment.
The RT6 also has information outputs that follow the inputs and outputs of the relay. These outputs will for example indicate if a gate is open or closed and if the safety relay needs to be reset.
The RT6 is designed with a minimum amount of components thus keeping both production costs and component acquisitions to a minimum.
Choose the RT6 to simplify your safety circuits and reduce your costs.
Applications:
Emergency Stops
Light Curtains
Three Position Devices
Interlocked Gates/Hatches
Magnetic Switches
Light Beams
Safety Mats
Contact Strips
Foot-Operated Switches
Features:
Five input options
Single or dual channel input
Manual supervised or automatic reset
Test input for supervision of external contactors
Width 45 mm
LED indication of supply, inputs, outputs, short-circuit and low voltage level
3 NO/1 NC relay outputs
Two voltage free transistor information outputs
24 VDC
24, 48, 115 or 230 VAC
Quick release connector blocks
RT7 Safety Relay
Universal Relay with Delayed 'Stop' Outputs
The RT7 is a universal relay that can be used to supervise both safety devices and the internal safety of your machinery. In addition, you can select the safety level that is required for each installation. All this is possible because the RT7 has the most versatile input options arrangement available on the market. The RT7 can therefore replace many other relays.
The RT7 has four (4 NO) dual safety outputs of which two may be delayed for up to three seconds in order to achieve a safe and 'soft' stop. A 'soft' stop allows machinery to brake and stop gently before power is removed. A 'soft' stop has many benefits: The machinery life will be prolonged, processed products will not be damaged, and restarts from the stopped position are made possible and easier.
Another option with the RT7 is manual or automatic resetting. A manual supervised reset is used for gates and other safety devices that can be bypassed, while an automatic reset is used for small safety hatches if deemed appropriate from a risk point of view.
In addition, the RT7 has information outputs that follow the inputs and outputs of the relay. These outputs indicate if for example a gate is opened or closed, if there is a delay or if the relay needs to be reset.
Choose the RT7 to simplify your safety circuits and reduce your costs
Applications:
Emergency Stops
Light Curtains
Three Position Devices
Interlocked Gates/Hatches
Magnetic Switches
Light Beams
Safety Mats
Contact Strips
Foot-Operated Switches
Features:
Five input options
Single or dual channel input
Manual supervised or automatic reset
Test input for supervision of external contactors
Width 45 mm
LED indication of supply, inputs, outputs, short-circuit and low voltage level
4 NO/1 NC relay outputs, 2 NO outputs can be delayed for soft stops
Delay times:
RT7A 0; 0.5; 1.0; 1.5 s
RT7B 0; 1.0; 2.0; 3.0 s
Three voltage free transistor information outputs
24 VDC
24, 48, 115 or 230 VAC
Quick release connector blocks