Greatest reference in our business is our successful past

GP · HP series

GP · HP series

GP · HP series is an easy exchange converter plug , DIN comes with an open circuit is protected to prevent easy rail mounting socket and current

Kind
Type name
Input
DC output
Load
Auxiliary power
Class
Conversion
AC voltage
VGP
AC 150; 300V
0 ~ 100mV
0 ~ 1V
0 ~ 5V
0 ~ 10V
1 ~ 5V
0 ~ 1mA
0 ~ 10mA
4 ~ 20mA
600Ω ~ ∞
600Ω ~ ∞
600Ω ~ ∞
1kΩ ~ ∞
600Ω ~ ∞
0 ~ 10kΩ
0 ~ 1kΩ
0 ~ 550Ω
DC 24V
AC 100/110V
AC 200/220V
DC 100/110V
0.5
Average rectified
AC voltage
VGP-E
AC 150; 300V
0.5
RMS rectifier
Alternating current
AGP
AC 5; 1A
0.5
Average rectified
Alternating current
AGP-E
AC 5; 1A
0.5
RMS rectifier
Frequency
FGP
45 ~ 65Hz
0.5
Average pulse
Power
1P2W
EHP-1
0.5; 1kW
AC 110; 220V 5A
0.5
Time-division multiplier
Power
1P3W
EHP-2
1; 2kW
AC 110; 220V 5A
Power
3P3W
EHP-3
1; 2kW
AC 110; 220V 5A
Reactive power
1P3W
RHP-1
± 0.5; 1kVar
AC 110; 220V 5A
0 ~ ± 100mV
0 ~ ± 1V
0 ~ ± 5V
0 ~ ± 10V
0 ~ 3 ~ 5V
0 ~ ± 1mA
0 ~ ± 10mA
4 ~ 12 ~ 20mA
600Ω ~ ∞
600Ω ~ ∞
600Ω ~ ∞
1kΩ ~ ∞
600Ω ~ ∞
0 ~ 10kΩ
0 ~ 1kΩ
0 ~ 550Ω
Reactive power
1P2W
RHP-2
± 1; 2kVar
AC 110; 220V 5A
Reactive power
3P3W
RHP-3
± 1; 2kVar
AC 110; 220V 5A
Power factor
1P2W
NHP-1
LEAD 0.5
LAG 0.5
AC 110; 220V 5A
2.0
Disable Power
Power calculation
Power factor
1P3W
NHP-2
LEAD 0.5
LAG 0.5
AC 110; 220V 5A
Power factor
3P3W
NHP-3
LEAD 0.5
LAG 0.5
AC 110; 220V 5A
 

 
More Info Price

GP series transducer

Resim Yok

TOYO KEIKI

GP series transducer has a plugin that allows easy maintenance or replacement body .
DIN socket makes it easier to work is because rail mounting .
Mechanical conversion module out of the plastic boxes that in lightweight, sturdy glass fiber , and prevent electrical stress

Kind
Type name
Input
DC output
Load
Auxiliary power
Class
Conversion
Alternating current
AGP-L
AC 5; 1A
0 ~ 100mV
0 ~ 1V
0 ~ 5V
0 ~ 10V
1 ~ 5V
0 ~ 1mA
0 ~ 10mA
4 ~ 20mA
600Ω ~ ∞
600Ω ~ ∞
600Ω ~ ∞
600Ω ~ ∞
600Ω ~ ∞
0 ~ 10kΩ
0 ~ 1kΩ
0 ~ 550Ω
DC 24V
AC100/110V
AC200/220V
DC100/110V
0.5%
Average rectified
(With limiter )
AGP-E (L)
RMS operation
(With limiter )
Resistor temperature
CGP
-200 ~ +500
0.5%
PT, JPT
Isolator
DGP
DC voltage , DC current
0.25%
 
DGP-L
With limiter
High speed
Isolator
DGP-F
 
DGP-FL
With limiter
DGP-R
 
DGP-RL
With limiter
Absolute Output
Isolator
DGP-V
0.25%
 
DC - Pulse
EGP
DC voltage , DC current
0.005-1000Hz
0.5,5,50 mSEC
0.5%
 
EGP-Z
667-10kHz
 
 
 
Frequency
FGP
45 ~ 65Hz
0 ~ 100mV
0 ~ 1V
0 ~ 5V
0 ~ 10V
0 ~ 5V
0 ~ 1mA
0 ~ 10mA
4 ~ 20mA
600Ω ~ ∞
600Ω ~ ∞
600Ω ~ ∞
600Ω ~ ∞
600Ω ~ ∞
0 ~ 10kΩ
0 ~ 1kΩ
0 ~ 550Ω
0.5%
 
Thermocouple
JGP
1200
0.5%
K, E, J, T, R, B, S, N
Potentiometer
Meters
KGP
100Ω ~ 10kΩ
0.5%
 
KGP-7
2-wire
 
Linearizer
LMP
DC voltage , DC current
0.5%
 
Discover Tri
Byuta
PGP
DC 4 ~ 20mA
0.25%
Supply DC24V
PGP-C
0.5%
No isolation
Kaiping calculator
QGP
DC voltage , DC current
0.5%
 
Revolution
(Pulse)
TGP
30kHz voltage pulse
0.5%
 
TGP-D
Sensor power supply
TGP-S
20kHz voltage pulse
Slow Pulse
Subtractor
UGP-(L)
DC voltage , DC current
0.5%
(With limiter )
AC voltage
VGP-(L)
AC 150; 300 V
0.5%
Average rectified
(With limiter )
VGP-E (L)
RMS operation
(With limiter )
Adder
WGP-(L)
DC voltage , DC current
0.5%
With limiter
Multiplier
XGP
DC voltage , DC current
0.5%
 
Divider
YGP
DC voltage , DC current
0.5%
 
First order lag
RAGP
DC voltage , DC current
0.5%
 
Pulse
Isolator
RBGP
ON, OFF pulse
Voltage pulse
Voltage pulse
Open
 
 
 
RBGP-D
Sensor power supply
Load Cell
RLGP
1mV / V
1.5mV / V
2mV / V
5mV / V
10mV / V
20mV / V
0 ~ 100mV
0 ~ 1V
0 ~ 5V
0 ~ 10V
1 ~ 5V
0 ~ 1mA
0 ~ 10 mA
4 ~ 20mA
600Ω ~ ∞
600Ω ~ ∞
600Ω ~ ∞
600Ω ~ ∞
600Ω ~ ∞
0 ~ 10kΩ
0 ~ 1kΩ
0 ~ 550Ω
DC 24V
AC100/110V
AC200/220V
DC100/110V
0.25%
 
Resistance - DC
RIGP
50Ω ~ 10kΩ
0.5%
 
Input selection
RFGP
DC voltage , DC current
0.25%
 
Linearizer
LMP
DC voltage , DC current
0.25%
Built-in microcomputer
Analog Memory
MMP
DC voltage , DC current
0.25%
Built-in microcomputer
Pikuhoruda
NMP
DC voltage , DC current
0.25%
Built-in microcomputer
Analog
Backup
RKMP
DC voltage , DC current
0.25%
Built-in microcomputer
Power
SGP
 
DC24V 100mA
 
AC100/110V
AC200/220V
 
 
Thermosensor
ZGP-A
 
 
 
 
 
For JGP
Current protection device
ZGP-B
5 A, 1A
 
 
 
 
For AGP
ZGP-D
+ input
For DGP
ZGP-D2
Input ±
For DGP
Flow divider
ZGP-C
100 ~ 360mA
 
 
 
 
For DGP

More Info Price

GS · GM Series

GS · GM Series

GS · GM Series AC-DC transducer isolator is to convert the DC signal transducer for measuring the amount of electrical unified range . Based on many years of experience in the field of measurement , the advice of a custom IC electronics , and the case is due to adopt a fire-retardant glass-reinforced plastic , and high safety and reliability .

This model is due to mounting , panel mounting ( screw mounting board ) and DIN rail mounting and the freedom to choose , you can now change. The amount of power , with pulse output transducers for measurement of reactive power and power factor transducers , such as adding some of the trends that can be used in the circuit , we make you more widespread use

Kind
Type name
Input
DC output
Load
Auxiliary power
Class
Conversion
AC voltage
VGS-A
AC 150; 300V
0 ~ 100mV
0 ~ 1V
0 ~ 5V
0 ~ 10V
1 ~ 5V
0 ~ 1mA
0 ~ 10mA
4 ~ 20mA
600Ω ~ ∞
600Ω ~ ∞
600Ω ~ ∞
1kΩ ~ ∞
600Ω ~ ∞
0 ~ 10kΩ
0 ~ 1kΩ
0 ~ 550Ω
AC 100/110V
AC 200/220V
DC 24V
DC 100/110V
Or self- powered
0.5
Average rectified
AC voltage
VGS-EA
AC 150; 300V
RMS rectifier
Alternating current
AGS-A
AC 5; 1A
Average rectified
Alternating current
AGS-EA
AC 5; 1A
RMS rectifier
Frequency
FGS-A
45 ~ 65Hz
Average pulse
Power
1P2W
1P3W
3P3W
3P4W
EGM-A
1; 2kW
AC 110/220V 5A
Time-division multiplier
Power
Pulse Outputs
1P2W
1P3W
3P3W
3P4W
WGM-A
Reactive power
1P2W
1P3W
3P3W
3P4W
RGM-A
± 1; 2kVar
AC 110; 220V 5A
0 ~ ± 100mV
0 ~ ± 1V
0 ~ ± 5V
0 ~ ± 10V
0 ~ 3 ~ 5V
0 ~ ± 1mA
0 ~ ± 10mA
4 ~ 12 ~ 20mA
600Ω ~ ∞
600Ω ~ ∞
600Ω ~ ∞
1kΩ ~ ∞
600Ω ~ ∞
0 ~ 10kΩ
0 ~ 1kΩ
0 ~ 550Ω
Reactive power
Pulse Outputs
1P2W
1P3W
3P3W
3P4W
QGM-A
Power factor
1P2W
1P3W
3P3W
3P4W
NGM-A
LEAD 0.5
LAG 0.5
3.0
Disable Power
Power calculation
AC voltage
VLS-OA
AC 150; 300V
0 ~ 1mA
0 ~ 1kΩ
Unnecessary
0.5
Average rectified
AC voltage
VLS-OCA
AC 150; 300V
0 ~ 1mA
0 ~ 10kΩ
Alternating current
ALS-OA
AC 5; 1A
0 ~ 1mA
0 ~ 1kΩ
Alternating current
ALS-OCA
AC 5; 1A
0 ~ 1mA
0 ~ 10kΩ
Isolator
DGS-A
DC0.1; 10V
DC1; 20mA
4 ~ 20mA
0 ~ 550Ω
AC 100/110V
AC 200/220V
DC 24V
DC 100/110V
0.25
Isolation between input and output

 
More Info Price

JP series signal converter

JP series signal converter

 JP series signal converter is to convert the DC signal transducer for measuring the amount of electrical unified range .
· JP Series signal converters , GP Series , PR based on the results of a multi-year series of signal converter , the advice of a custom electronic circuit IC , compact, lightweight , they achieve higher reliability and safety Masu .
· JP Series signal converters , it uses a completely flame-retardant plastic , you can use your confidence.
· JP series signal converter , easy to handle , easy to change specifications and also supports adopted a plug-in terminal construction

 

Kind
Type name
Input
DC output
Load
Auxiliary power
Class
Conversion
Alternating current
AJP-E
AC 5A, 1A
0 ~ 100mV
0 ~ 1V
0 ~ 5V
0 ~ 10V
1 ~ 5V
0 ~ 1mA
0 ~ 10mA
4 ~ 20mA
Output EJP
0.1Hz ~ 1000Hz
600Ω ~ ∞
600Ω ~ ∞
600Ω ~ ∞
2kΩ ~ ∞
600Ω ~ ∞
0 ~ 10kΩ
0 ~ 1kΩ
0 ~ 750Ω
DC 24V
AC 100/110V
AC 200/220V
DC 100/110V
0.5
True RMS operation
AJP-EL
with limiter
Resistor temperature
CJP
Resistance-temperature detector
0.3
PT, JPT
CJP-L
with limiter
-1 isolator output
DJP
DC voltage and current
0.2
 
DJP-L
With limiter
-2 isolator output
WDJP
DC voltage and current
0.2
 
WDJP-L
With limiter
DC - Pulse
EJP
DC voltage and current
0.5
 
Thermoelectric temperature
JJP
Thermoelectric bodies
0.5
K, E, J, T, R, B, S, N
JJP-L
With limiter
Potentiometer
KJP
100Ω ~ 10kΩ
0.3
100Ω ~ 10kΩ
KJP-L
With limiter
Revolution
TJP
AC voltage pulse
0.5
 
TJP-L
With limiter
Revolution
TJP-D
AC voltage pulse
0.5
Sensor power supply
TJP-DL
with limiter
Subtractor
UJP-E
DC voltage and current
0.5
 
UJP-EL
With limiter
AC voltage
VJP-E
AC 150,300 V
0.5
True RMS operation
VJP-EL
with limiter
Adder
WJP
DC voltage and current
0.5
 
WJP-L
With limiter

More Info Price

SHA multiple transducers

SHA multiple transducers

SHA multiple transducers form the wiring in one system can simultaneously measure the amount of electricity and various power -frequency voltage, current, power factor and reactive power , power is a form of high-density transducer .

Pulse output can be implemented two analog outputs and up to 10 points .

Kind
Type name
Input
DC output
Load
Auxiliary power
Remarks
1P2W
V
A
Hz
W
Var
COSφ
W Demand
A demand
Wh
Varh
SHA

AC 150; 300V
AC 5A
45 ~ 65Hz
500; 1kW
500; 1kVar
1 to 0.5 ~ 0.5
500; 1kW
AC 5A
By specifying
By specifying
V; A; W; Hz

0 ~ 100mV
0 ~ 1V
0 ~ 5V
0 ~ 10V
1 ~ 5V
0 ~ 1mA
0 ~ 10mA
4 ~ 20mA


Var; COSφ

0 ~ ± 100mV
0 ~ ± 1V
0 ~ ± 5V
0 ~ ± 10V
0 ~ 3 ~ 5V
0 ~ ± 1mA
0 ~ ± 10mA
4 ~ 12 ~ 20mA


600Ω ~ ∞
600Ω ~ ∞
2.5kΩ ~ ∞
5kΩ ~ ∞
2.5kΩ ~ ∞
0 ~ 10kΩ
0 ~ 1kΩ
0 ~ 600Ω




600Ω ~ ∞
600Ω ~ ∞
2.5kΩ ~ ∞
5kΩ ~ ∞
2.5kΩ ~ ∞
0 ~ 10kΩ
0 ~ 1kΩ
0 ~ 600Ω
DC 24V
AC 100/110V
AC 200/220V
DC 100/110V
Class
0.5
(Only Cosφ 2.0)
 
1P3W
V × 2
A × 2
Hz
W
Var
COSφ
W Demand
A demand
Wh
Varh

AC 150; 300 V
AC 5A
45 ~ 65Hz
1; 2kW
1; 2kVar
1 to 0.5 ~ 0.5
1; 2kW
AC 5A
By specifying
By specifying
3P3W
V
A
Hz
W
Var
COSφ
W Demand
A demand
Wh
Varh

AC 150; 300V
AC 5A
45 ~ 65Hz
1; 2kW
1; 2kVar
1 to 0.5 ~ 0.5
1; 2kW
AC 5A
By specifying
By specifying
3P4W
V
A
Hz
W
Var
COSφ
W Demand
A demand
Wh
Varh

AC 150; 300 V
AC 5A
45 ~ 65Hz
1; 2kW
1; 2kVar
1 to 0.5 ~ 0.5
1; 2kW
AC 5A
By specifying
By specifying
 

More Info Price

XP series signal converter

XP series signal converter

TOYO KEIKI

XP series signal converter is a signal converter that converts the output signal for measuring two isolated DC unified various electrical signals .
XP series signal converter , the overall flame retardant resin used is a signal converter availability and security control .
XP series signal converter , easy handling, plug-in structure has been adopted and also supports easy specification change . Less adherence to self-heating installation (52mm spacing ) is possible

Kind
Type name
Input
DC output
Load
Auxiliary power
Class
Conversion
Alternating current
AXP-E
AC 5; 1A
0 ~ 100mV
0 ~ 1V
0 ~ 5V
0 ~ 10V
1 ~ 5V
0 ~ 1mA
0 ~ 10mA
4 ~ 20mA
600Ω ~ ∞
600Ω ~ ∞
600Ω ~ ∞
600Ω ~ ∞
600Ω ~ ∞
0 ~ 10kΩ
0 ~ 1kΩ
0 ~ 550Ω
DC 24V
AC 100/110V
AC 200/220V
DC 100/110V
0.5%
RMS operation
AXP-EL
with limiter
Resistor temperature
CXP
600
0.3%
PT, JPT
CXP-J
600
0.3%
PT, JPT fast form
Isolator
DXP
DC 10V, 4 ~ 20mA
0.25%
 
DXP-L
With limiter
High speed
Isolator
DXP-J
 
DXP-JL
With limiter
Rivers
Isolator
DXP-R
 
DXP-RL
With limiter
Thermocouple temperature
JXP
1200
0.5%
K, E, J, R
Potentiometer
Meters
KXP
100Ω ~ 10kΩ
0.2%
 
KXP-L
With limiter
KXP-J
Fast form
KXP-JL
Fast shape with limiter
Discover Tri
Byuta
PXP
DC 4 ~ 20mA
0.25%
 
PXP-J
Fast form
PXP-L
With limiter
PXP-JL
Fast shape with limiter
Revolution
(Pulse)
TXP
30kHz voltage pulse
0.3%
 
TXP-SD
Sensor power supply
TXP-SDL
with limiter
TXP-S
20kHz voltage pulse
Slow Pulse
TXP-SL
with limiter
AC voltage
( RMS calculation )
VXP-E
AC 150; 300 V
0.5%
RMS operation
VXP-EL
with limiter
Pulse
Isolator
RBXP
ON, OFF pulse
Voltage pulse
Voltage pulse
Open
 
 
Noninverted output
RBXP-D
, sensor power supply
RBXP-R
Inverted output
RBXP-RD
, sensor power supply
Thermosensor
ZXP-A
 
 
 
 
 
For JXP
Current protection device
ZXP-B
5A, 1A
 
 
 
 
For AXP
ZXP-D
 
For DXP
Flow divider
ZXP-C
100 ~ 360mA
 
 
 
 
For DXP

More Info Price

XR series converter

XR series converter
TOYO KEIKI
XR series converter rack converter assembly is suitable for multi-point measurement systems in the field of computerized industrial process measurement .

Converter group , the 19-inch rack " width 480mm, JIS C 6010 (1989, Japan ) and , EIA-310-C (1982, USA) employing standard gauge " is housed . Electrical performance , and other terms , JIS C 1111 (AC-DC transducer ) are to apply . Especially needed items are provided separately.
Industrial Process Instrumentation , DCS 1 for a set of transducers . 2 multi-point measurement . instrumented systems can be configured to suit various purposes any combination of the measurement . Power supply ( bulk output ) modules and XR-□ S Io form the bulk output connector also has a computer instrument . Converter can accommodate up to 16 channels .

XR Series rack converter output configuration is below three .
 
Output Configuration
How to retrieve output
Output 1
Second output
Terminal Blocks Pin 5-6
Pin terminal block 7,8
The bulk connector output
1
1 Output Isolation
No
No
2
2 isolated outputs
No
3
3 Output Isolation
The bulk connector output is computer instrumentation .
Two output method because it is isolated , for the output of existing loops can provide output to computer input .
The first output terminal front ( 5-6 pin) to the front the second output terminal ( pin 7-8 ) and are printed in both 40-pin connector on the right front . The output of one indicator , such as loop recorder , such as possible ways to control the output of the other loop . The other output can be shorted output in an accident while helping to improve the reliability of instrumentation systems , so the impact Ukemasen . (If the output voltage , short circuit withstand permanent loads . ) bulk power from power supply terminal is on the right front of the converter module group 16. Type of power , DC24V system , AC100V system , AC200V system , DC100V can choose from four different systems do not need another external power supply .
 
Kind
Type name
Input
DC output
Load
Auxiliary power
Class
Conversion
Alternating current
( RMS calculation )
AXR-E
AC 5; 1A
0 ~ 100mV
0 ~ 1V
0 ~ 5V
0 ~ 10V
1 ~ 5V
0 ~ 1mA
0 ~ 10mA
4 ~ 20mA
1kΩ ~ ∞
1kΩ ~ ∞
1kΩ ~ ∞
1kΩ ~ ∞
1kΩ ~ ∞
0 ~ 10kΩ
0 ~ 1kΩ
0 ~ 550Ω
DC 24V
AC 100/110V
AC 200/220V
DC 100/110V
0.5%
 
AXR-EL
With limiter
Resistor temperature
CXR
600
0.3%
PT, JPT
Isolator
DXR
DC voltage , DC current
0.25%
 
DXR-L
With limiter
High speed
Isolator
DXR-J
 
DXR-JL
With limiter
Thermocouple temperature
JXR
Thermocouple
0.5%
K, E, J, T, R, B, S, N
DC - Pulse
EXR
DC voltage , DC current
0.05 ~ 1000Hz
0.5,5,50 mSEC
0.3%
 
Potentiometer
Meters
KXR
100Ω ~ 10kΩ
0 ~ 100mV
0 ~ 1V
0 ~ 5V
0 ~ 10V
1 ~ 5V
0 ~ 1mA
0 ~ 10mA
4 ~ 20mA
1kΩ ~ ∞
1kΩ ~ ∞
1kΩ ~ ∞
1kΩ ~ ∞
1kΩ ~ ∞
0 ~ 10kΩ
0 ~ 1kΩ
0 ~ 550Ω
0.2%
 
Discover Tri
Byuta
PXR
DC 4 ~ 20mA
0.25%
 
Revolution
(Pulse)
TXR
30kHz voltage pulse
0.3%
 
TXR-L
With limiter
Subtractor
UXR
DC voltage , DC current
0.2%
 
UXR-L
With limiter
AC voltage
( RMS calculation )
VXP-E
AC 150; 300 V
0.5%
 
VXP-EL
With limiter
Adder
WXR
DC voltage , DC current
0.2%
 
WXR-L
With limiter
Single-phase power
REXR
AC 110; 5 A
0.5%
Output Type 1
DC power
RPXR
DC 110V, 5 A
0.3%
 
RPXR-L
With limiter
Through Card
SXR-A
250Ω
 
 
 
 
 
Thermosensor
ZXR-A1
5A, 1A
 
 
 
 
For JXR

 

More Info Price

TOYO KEIKI MARKASINA A?T ?R?N GRUPLARI

Transducer
Transducer