Çalışmalarımızdaki en büyük referansımız, geride bıraktığımız başarı dolu

Migatron

Migatron Products

Self Contained Sensors

Self contained sensors are devices where the sensor and the controller are built into the same unit.

Migatron RPS-150
Ranges: 2-40", 5-80"
Broad beam
On/off output with analog capability
Migatron RPS-150A
Ranges: 2-40", 5-80"
Broad beam
Analog output
Migatron RPS-400-6
Range: 2-6"
Narrow Beam
Three wire NPN transistor output

Migatron

RPS-400-30 Sensor
Self Contained
Sensing Range 5-30"
Narrow Sensing Beam
Migatron RPS-401,426
Ranges: 4-40", 8-80"
Narrow beam
On/off output
Migatron RPS-401A,426A
Ranges: 4-40", 8-80"
Narrow beam
Analog output
Migatron RPS-401A-80P
Ranges: 8-80"
Narrow beam
Analog output
Migatron RPS-409A
Ranges: 4-40", 6-80" and 10-144"
Analog output
Temperature compensation
Sync/enable option

Migatron

RPS-409A-IS
Ranges: 4-40", 6-80", 12-144", 12-216"
Analog output
Intrinsically Safe Design
UL Listed

Migatron

RPS-412A
High accuracy analog ultrasonic sensor (±0.002" or 0.05% of range, which ever is greater, at 25°C).
Migatron RPS-450,475
Ranges: 5-30", 10-72"
Proximity sensor

Migatron

TBT/TBR-600
Range: 0-40"
Thru beam
On/off output
Adjustable. count rate
Migatron RPS-3000/4000
Range 2-40 feet
Analog output
Temperature compensation

RPS-412A
HIGH ACCURACY SENSOR

Features

  • Input Voltage 20-30 VDC
  • Analog Voltage Output
  • Short Circuit Protected
  • Wide Temperature Range
  • Temperature Compensation
  • Self Contained Sensor
  • Quick Disconnect Connector
  • Stainless Steel Housing
Migatron

The RPS-412A is a high accuracy analog ultrasonic sensor (±0.002" or 0.05% of range, which ever is greater, at 25°C). The sensor has a built in temperature compensation target, that monitors and compensates for air temperature 50 times per second. The sensor also compensates for changes in relative humidity, changes in barometric pressure, and other factors that influence the speed of sound.

 

The RPS-412A has a 47mm stainless steel barrel housing. The stainless steel housing is electrically isolated from the sensor electronics. The sensor comes with two jam nuts for mounting.

The RPS-412A has a 0-10V analog output. The analog output is fixed. The RPS-412A-16 is 0.625V per inch. The RPS-412A-10 is 1.000V per inch. For example using the 3-16" range version, a target placed 3 inches from the sensor face will result in a sensor output of 1.875V. A target placed 16 inches from the sensor face will result in a sensor output of 10.0V.

The RPS-412A is designed to take advantage of today's PLC and computer analog input cards. The analog input card will determine the resolution of the system. The numerical values programmed into the PLC or computer will determine the zero and span.

SPECIFICATIONS

Model:                       Range:            Volts per Inch:
RPS-412A-10-V         3" -10"               1.000V
RPS-412A-16-V         3" -16"               0.625V


Accuracy:  ±0.002², or ± 0.05% of range (which ever is greater) @ 25ºC.
                  ±0.2% of range from 0 to 50ºC

Power Input: 20 to 30VDC Reverse Polarity Protected

Input Current: 65mA Typical

Operating Temperature: 0 to 50ºC

Output:  Analog Voltage Output

Short Circuit Protected

Output Referenced to Power GND or Signal GND

Load 500 Ohms to Infinity

Frequency: 60kHz

 

Housing Material: Stainless Steel with PVC Head

Sample Rate: 20ms Typical

Update Time: 2s Maximum

Weight: 22 oz. (shipping weight 3 lbs.)

Figure:
A- Wiring Diagram
B- Back View of Sensor
C- Connector Diagram
D- Housing Diagram

PART NUMBER RANGE OUTPUT DESCRIPTION
RPS-412A-10-V
RPS-412A-16-V
3" to 10"
3" to 16"
0 - 10VDC Analog Output
0 - 10VDC Analog Output
F32-5070042
F32-5070053
F32-5070094
  6' Snap-In Cable, Straight (sold separately)
6' Locking Cable, Straight (sold separately)
6' Locking Cable, Right-Angle (sold separately)

SENSOR SETUP

Air Temperature:

The air temperature between the sensor and target must be constant. Any variations in air temperature will compromise the accuracy. The sensor can compensate for changes in air temperature provided the air temperature is constant between the sensor and target. If the air temperature varies between the sensor and target (For example if the air temperature is 20°C from the sensor face to half way to the target, and the air temperature is 25°C for the remainder of the distance) the sensor cannot compensate for the temperature variation.

Sensor Alignment:

The sensor must be aligned to obtain the best accuracy. To align the sensor place the target you will be measuring at the farthest distance it will be from the sensor. Monitor the color of the LED on the sensor (green is no signal, light red is a weak signal, and bright red is a strong signal) align the sensor, so the LED is the brightest red color you can get. This will be the optimum alignment of the sensor.

Calibration:

The sensor comes pre calibrated from the factory. The sensor may be recalibrated in the field.

Follow the steps below to recalibrate.

1. Sensor alignment must be done before calibration.

2. P1 must be adjusted first.

3. Place the target at the near distance (closest distance target will get to sensor). Measure the distance from the target to the transducer face (DO NOT TOUCH THE FACE OF THE TRANSDUCER).

4. Calculate the voltage for the near distance. Multiply the distance by the volts per inch. Adjust P1 for the calculated voltage.

5. Place the target at the far distance (farthest distance target will be from sensor). Measure the distance from the target to the transducer face.

6. Calculate the voltage for the far distance. Multiply the distance by the volts per inch. Adjust P2 for the calculated voltage.

7. Repeat the adjustment of P1 and P2 to check for accuracy.

Close Range Sensors

Detect objects within 2 to 6 inches of the sensor.

Migatron

RPS-400-30 Sensor     
Self Contained Sensor
Sensing Range 5-30"
Narrow Sensing Beam

Migatron RPS-400-6
Range: 2-6"
Narrow Beam Sensor
Three wire NPN transistor output
Migatron RPS-100
Ranges: 2-14", 5-72", 10-240"
Broad Beam Sensor
On/Off Output with analog capability

 

Migatron RPS-102
Ranges: 2-14", 5-72", 10-240"
Broad Beam Sensor
On/Off Output
Migatron RPS-150
Ranges:  2-40", 5-80"
Broad Beam Sensor
On/Off Output
Migatron RPS-150A
Ranges:  2-40", 5-80"
Broad Beam Sensor
0 - 10VDC and 4 - 20 mA Analog Output
Migatron RPS-2100
Ranges: 2-14", 5-72", 10-240"
Broad Beam Sensor
On/Off Output

Intrinsically Safe and Explosion Proof Sensors

Ultrasonic sensors for use in environments classified as hazardous.

Migatron RPS-409A-IS 
Ranges: 4-40", 6-80", 12-144", 12-216"
Narrow Beam
0 - 10 VDC Analog Output
Migatron RPS-326-X
Ranges: 24-72", 24-240"
Narrow Beam
On/Off Output with analog capability

Controllers With Remote Sensing Heads

These are devices where the sensor and the controller are separate units and can be located in separate locations.

Migatron RPS-100  
Ranges: 2-14", 5-72", 10-240"
Broad beam sensor
On/off output with analog capability
Migatron RPS-102
Ranges: 2-14", 5-72", 10-240"
Broad beam sensor
On/off output, dual transducers
Migatron RPS-300
Ranges: 4-14", 5-36", 8-72"
Narrow beam sensor
on/off output with analog capability
Migatron RPS-300T Teflon ®
Ranges: 4-14", 5-36"
Narrow beam sensor
On/off output with analog capability
Migatron RPS-302
Ranges: 4-14", 5-36", 8-72"
Narrow beam sensor
On/off output
Migatron RPS-322
Range: 8-72"
Narrow beam sensor
Dual transducers, on/off output
 Migatron RPS-325
Range: 8-72"
Narrow beam sensor
On/off output with analog capability, sealed transducer
Migatron RPS-326
Range: 24-72", 24-240"
Narrow beam sensor
Explosion-proof
On/off output with analog capability
Migatron RPS-500
Analog ranging card
Zero, span, sample, and hold controls
Migatron RPS-2100
Ranges: 2-14", 5-72", 10-240"
Broad beam sensor
On/off output
Migatron RPS-2300
Ranges: 4-14", 5-36", 8-72"
Narrow beam sensor
On/off output
Migatron RPS-2325
Range: 8-72"
Narrow beam sensor
On/off output
steel transducer
Migatron RPS-8000
Ranges: 4-12", 5-36", 8-72"
Multiplexed: 2-8 transducers
Narrow beams sensor
On/off output

Set Point Controllers

  • These are control devices that have adjustable set points.
  • You can set the controller with from one to four set points.
Migatron M-1000
An analog controller with four individual set-points and temperature compensation.
Migatron SPC-701 
Set point controller One adjustable set point.
Migatron SPC-704
Set Point Controller Four adjustable set points
Migatron hakkında daha fazla bilgi için tıklayınız.