Çalışmalarımızdaki en büyük referansımız, geride bıraktığımız başarı dolu

TAKIKAWA -Controller

Outside Dia. Control System

  • These units are to control diameter by outputting feed-back signals to extruding machine or winding machine in continuous extruding molding production line.
  • Among the range, there are DAC-76A(Step delay control type), DAC-86B(PI control type) and DAC+88(Automatic starting-up type).
  • There is LDM-210C that builds the control unit into the measuring instrument of the LASER DIAMETER. @
  • Among the range, there is deformed material extruding control system for keeping shape of profile constant of extruding plastic or resin

Outside Dia. Control System

 

Model DAC-86B DAC-76A DAC+88 LDM-210C
(Dia.Control Part)
Control
method
P/I/SPEED
Control
Step delay
Control
Parameter
Control
Selected
P/I Control or Step delay Control
Automatic
starting-up
NG NG OK NG
Applicable
Micrometers
All devices which have
Analog deviation output
Only LDM-Series Included LDM
Input kinds Error input,
Line speed input
Error input, Extruder input,
Capstan input
Line speed input
Input isolation OK OK OK OK
Input range
[DCV]
Error: +/-10V
Line speed: +10V
Error: +/-10V Extruder: +10V
Capstan: +10V
Line speed: +10V
Input impedance 200k ohm 200k ohm 200k ohm 200k ohm
Error
gain setting
NG 10um/V-10mm/V
(decade steps)
NG NG
Output kinds Control output Control output Extruder output,
Capstan output
Control output
Output method Deviation control Deviation control Absolute control Deviation control
Output isolation OK OK OK OK
Output range DC+/-10V DC+/-10V DC+/-10V DC+10V
(Ext./Cap. each)
Max. current DC+/-20mA DC+/-20mA DC+10mA
(Ext./Cap. each)
DC+/-20mA
Output impedance less than 6 ohm less than 6 ohm less than 10 ohm
(Ext./Cap. each)
less than 6 ohm
Output limit
setting
OK OK OK OK
Setting items P,I Alarm,P System data(11items)[*1]
Work data(12items)
P,I or
P,Speed voltage,Distance
Programing
function
NG NG OK
(100 kinds)
NG
Operation button MANU/AUTO
/RESET
MANU/AUTO
/RESET
MANU/AUTO/UP/DOWN MANU/AUTO
External remote input OK OK OK OK
Pulse signal
of length
Unnecessary Necessary Unnecessary Unnecessary
Main display Output display
by LED bargraph
Output display
by analog meter
Operation state
display by LCD
Output display
by LED bargraph
RS-232C OK NG OK OK
Tacho-generator
input
NG OK NG NG
Power supply AC100-240V 50/60Hz Free power supply
Power
consumption
less than 8VA less than 15VA less than 10VA less than 20VA
Ambient condition Temperature:0-45 degree centigrade,
Humidity:30-85%(No condensation)
Outside dimension
W * H * D[mm]
144 * 72 * 191 350 * 99 * 331 144 * 72 * 191 144 * 72 * 241
Weight Approx. 1.5kg Approx. 3kg Approx. 1.7kg Approx. 1.8kg
  • [*1]Those data are backed up by battery, and not necessary to set for each product.

Defromed material extruding control system Specificaion

Summary This system is for keeping shape of profile constant through direct compensation/control of extruding machine or drawing machine by measuring in Non-contact method a discrepancy from standard value of profile to be extruded with a detecting head to be set just behind extruding machine at the time when extruding plastic or resin.
Edge sensor Sensing method Non-contact/Infrared optical fiber sensing
PRF-10H

PRF-40H
Measuring range 1mm * 20mm(PRF-10H),
4mm * 20mm(PRF-40H)
Resolution +/-1um
Accuracy +/-5um
Operation temperature Max. 300 degree centigrade
Outside dimension 360(W) * 45(H) * 20(D)[mm]
Weight 400g
Controller Deviation indicator Analog meter
+/-0.5mm(PRF=10H), +/-2mm(PRF-40H)

PRF-93
Deviation output DC voltage(Range: -4V to +4V)
4V/0.5mm(PRF-10H)A4V/2mm(PRF-40H)
High/Low limit output Muti-level setting available, Contact output 250V 1A
Power supply AC100`240V 50/60Hz 10VA
Outside dimention 144(W) * 72(H) * 191(D)[mm]
Weight 1.5kg
Control unit DAC-86B(See Spec. of DAC-86B)
Sensor mounting metals Option
PRF-93@@@@
   PRF-10H@@@
   PEF-40H@@@

TRAVERSE CONTROLLER

TRAVERSE CONTROLLER (TRC-10)
This is a device to control Traverse motion of Winding drum.
This device is to output Traverse speed voltage in proportion to its pulse
frequency number through receiving a rotation pulse of winding drum

Specifications

 

Type Traverse Controller
Model TRC-10
Summary This controller can control traverse motion when widing up
cables to cable drum. Control output is proportional voltage to
widing up speed.
Display Position/Setting, State(RUN/WAIT), Direction
Data setting Drum width, Pitch, Stop angle, Max. speed,
Pulse rate, Output fine adjustment
Volume setting Wide movement value, Frame movement value
Pulse input A/B Phase(0.01 - 50kHz), Single phase pulse available,
DC+12V[Max.40mA] Power supply avaelable
Extrenal input Quick feed, Wide movement, Position reset, Frame movement,
Emergency stop, Turn, Normal traverse, Reverse traverse start
Traverse output Max.+/-10VDC(Resolution : 12 bits)
Fixed voltage
output
+/-10VDC 2 channel, DC0 - +10V 2 channel
(Adjustable by volume at rear panel)
Contact output A direction, B direction
AC250V/DC30V 10A DC30V (Resistance load)
Power supply AC100 - 240V 50/60Hz 5VA
Ambient
condition
Temperature:0 - 45degree centigrade,
Humidity:35 - 85%RH(No condensation)
Outside
dimension
144(W) * 72(H) * 191(D)[mm]
Weight Approx. 1.5kg

PRESET CONTROL COUNTER

Preset Control Counter (PR-06)
PR-06 is 6-digit up/down counter for production line that is
available to set Preset-1(Forecasted value) as deviation from
full value, and Preset-1 value can be controled by line speed

Specifications

 
Type Preset Control Counter
Model PR-06
Summary PR-06 is 6-digit up/down counter for production line that is
available to set Preset-1(Forecasted value) as deviation from
full value, and Preset-1 value can be controled by line speed.
Method Double preset type up/down counter
Display 6-digt 7-segment LED, Zero suppressed
Preset-1 Forecasted value:4-digit setting(Setting deviation from full value), Contact/Non-contact output available
Preset-2 Full value:4-digit setting, Contact/Non-contact output available
Contact output DC30V/AC250V 1A(Resistance load),
Delay:Less than 20msec
Non-contact output Open-collector output(Max.35V 50mA Negativ logic),
Delay:Less than 10msec
Output function One shot or Hold(Cancel by reset)
Pulse input A/B phase, Single phase pulse available,
Driving current:More than 5mA,
DC+12V(50mA) Power supply available
Max. frequency 30cps/2kcps(alternative), Duty 1:1
Manual reset From push switch on front panel(More than 50msec)
External reset Short-circuited terminal(More than 50msec)
Inhibit input Short-circuited terminal or 'L' level input to terminal
(Recovery time: Less than 590usec)
Power supply AC100V/200V 50/60Hz 10VA
Ambient condition Temperature:-10 - 45degree centigrade,
Humidity:35 - 85%RH(No condensation)
Outside dimension 144(W) * 72(H) * 138(D)[mm]
Weight Approx. 1kg

Reverse Detector OM Series

Reverse Detector (OM-01)
This detector can output alarm by detecting reverse motion of winding direction in winding system and can be installed on DIN rail.

A/B Phase Divider (OM-02)
This device is to obtain 1/10 and 1/100 deviding output of single phase or A/B phase input pulse and can be installed on DIN rail.

2-Channels Distributor (OM-03)
This device has 2 channel input and 5 output for each pulse input and can be installed on DIN rail.

Specifications

 

 

Type Reverse Detector
Model OM-01
Summary This detector can output alarm by detecting reverse motion of winding direction in winding system and can be installed on DIN rail.
Power supply DC+12V/0.5A(Changeable by option)
Reverse count Setting 3-digit digital switch
Contact output 1-a contact, 590ms one shot, AC240V 1A(Resistance load)
Pulse input A/B phase pulse
Max. frequency 5kHz(Changeable by option)
Display Power on LED and Reverse detecting LED
Inhibit input Short-circuited terminal or 'L' level input to terminal
(DC5V/CMOS level)
Outside dimension 100(W) * 70(H) * 112(D)[mm], Installing on DIN rail available

 

 

Type A/B Phase Divider
Model OM-02
Summary This device is to obtain 1/10 and 1/100 deviding output of single phase or A/B phase input pulse and can be installed on DIN rail.
Power supply DC+12V/0.5A(Changeable by option)
Dividing ratio 1/10 and 1/100
Output Open collector output
Pulse input A/B phase pulse
Max. frequency 10kHz(Changeable by option)
Single/2 phase changing Changing by jumper on internal PCB
Outside dimension 100(W) * 70(H) * 112(D)[mm], Installing on DIN rail available

 

 

Type 2-Channels Distributor
Model OM-03
Summary This device has 2 channel input and 5 output for each pulse input and can be installed on DIN rail.
Power supply DC+12V/0.5A(Changeable by option)
Input 2 channels(Pulled-up by 4.7kohm resistances)
Output 5-outputs/1-channel(Open collector output)
Max. frequency 10kHz(Changeable by option)
Outside dimension 100(W) * 70(H) * 112(D)[mm], Installing on DIN rail available

 

Changeable Constant Current Source

Changeable Constant Current Source (VI-101,102)
Special power source to control brake or clutch by input voltage in production line.

 

Type Changeable Constant Current Source
Model VI-101 VI-102
Summary Special power source to control brake or clutch by input voltage in production line.
Input voltage DC 0 - +10V
Output current DC0 - 1A(Changeable range:0.1 - 1A), Ripple:Max. 0.5% DC0 - 2A(Changeable range:0.2 - 2A), Ripple:Max. 0.5%
Max. output voltage DC+25V DC+28V
Withstand voltage
(in-out)
+/-2000Vp
Circuit type Serial CMOS Power transistors circuit
Power supply AC200V(AC100V available by option) 50/60Hz 30VA AC200V(AC100V available by option) 50/60Hz 60VA
Operation temperature -5 - 50 degree centigrade
Outside dimension 130(W) * 85(H) * 102(D)[mm] 180(W) * 144(H) * 84(D)[mm]
Weight 1.0kg 1.5kg

 

TAKIKAWA -Controller

 

 

TAKIKAWA -Controller Ürünleri ile uygun rekabetçi fiyaları almak için müşteri temsilçimiz ile  http://www.imajteknik.com.tr/bize-ulasin veya Fiyat teklifi formunu doldurarak mesaj bırakmanız halinde satış muhendislerimiz en kısa zamanda sizinle irtibat kuracaklardır.

 

TAKIKAWA -Controller hakkında daha fazla bilgi için tıklayınız.